background image

1

STYLE 8840 HI CYCLE ELECTRIC VALVE 

INSTRUCTIONS AND PARTS LIST

GENERAL INFORMATION

The Style 8840 Valve utilizes a flat ball concept providing an open area greater than a typical 4” waterway. This design features a 4” long body and has 
easy operation with limited friction loss.

The valve has the Swing-Out™ feature and is designed for easy service with only one seat and an aluminum bronze flat ball which will rarely need to be 
changed.

The valve has a rated working pressure of 250 PSI in the flow direction, but will hold 100 PSI in the reverse direction. It is hydrostatically rated at 500 
PSI.

This valve is single directional and must be installed with the 250 PSI directional arrow (cast on valve body) pointing away from the pump regardless if it 
is for discharge or intake applications.

NOTE:  If the valve is used as an intake, it must be installed with the 250 psi directional arrow towards the swivel intake.

The electric actuator is reduced to 25:1 and will travel from full open to full close in approximately 8-10 seconds.

INSTALLATION

1.  Plumb into the pump system as usual being sure to heed the flow directional arrow cast on the body.
2.  The actuators can be mounted in one of four positions. 
3.  Keep the piping aligned so undue stresses are not placed on the valve. Victaulic connections in lieu of pipe threads do help.
4.  Be sure the white flange seal rings are in place before installing the valve. Close the flat ball before attaching flanges to body.
5.  Snug up flange bolts alternately (not adjacently) when securing flanges to valve body. Tighten each to 60-70 foot pounds. (Also alternately)
6.  Electric actuators should be installed in a direction where the manual override is accessible.
7.  If any welding is to be done on the truck, disconnect electrical connections until welding is finished.

NOTE:  If the actuators are removed for repositioning, always use Loctite 222 or Permabond LM113 on the mounting screws.

NOTE:   Pressures over 100 psi in the direction opposite to the arrow cast into the body could allow a small volume of water to pass through the valve 
on the upstream side.  Back pressures up to 250 psi, will not affect the valve seating system or fire pump.

PRESSURE TRANSDUCER

Use a thread seal and tighten only until snug plus an extra 1/8 to 1/4 turn.  Over tightening of the metal fitting may cause a slight zero shift.

CAUTION: Reverse excitation will permanently damage the unit.  Follow the wiring instructions carefully.

TANK FILL CONTROLLER DIP SWITCH SETTINGS

120578

Содержание Style 8840

Страница 1: ...dy 2 The actuators can be mounted in one of four positions 3 Keep the piping aligned so undue stresses are not placed on the valve Victaulic connections in lieu of pipe threads do help 4 Be sure the w...

Страница 2: ...he tank is above the set point the controller moves the motorized valve in the closed direction As long as the water level stays above the set point the controller continues to close the valve until a...

Страница 3: ...of the valve External LEDs can be plugged into the logic box at the LEDs connector and will duplicate the function of the on board LEDs The current limiting resistors are built onto the board so ordin...

Страница 4: ...the Transducer connector is correctly mated with its receptacle 4 Replace the pressure transducer if the problem persists Tank Fill Valve Does Not Open Tank Remains Empty 1 Make sure the Tank Fill Val...

Страница 5: ...When the Opened switch is activated by the sector gear the LED will blink slowly at once a second Normally the valve will stay in this position but after 5 seconds the valve may open to the hard stop...

Страница 6: ...tly Opened switch does not appear to be working 1 Check the wiring to make sure that voltage is going out to the switch and that the return from the switch is going into terminal TB3 27 Make sure that...

Страница 7: ...B B A B C A B C VIEW B B TYPICAL 1 SEALING PLUG GND POWER A B C A B C VIEW C C TYPICAL 3 SEALING PLUG OPEN VALVE CLOSE 3 POSITION DEUTSCH 2 POSITION DEUTSCH 5 POSITION DEUTSCH SYSTEM VDC SYSTEM VDC S...

Страница 8: ...CHES 4 POSITION DEUTSCH 1 2 4 3 SYSTEM VDC CLOSED OPENED SYSTEM VDC CONNECTOR DTM06 4S E007 SOCKET 0462 201 20141 WEDGE LOCK WM 4S A B C D E A B C D E GREEN RED VIEW D D TYPICAL 1 WHITE BLACK DRAIN PR...

Страница 9: ...TATION GRN SIGNAL ALGORITHM SELECTOR JUMPER WHITE OUT TO NO VOLTAGE COUNTER GRY OUT TO NO VOLTAGE COUNTER GRY VEHICLE GROUND BLK SYSTEM VDC VEHICLE BATTERY RED SYSTEM VDC OUT TO LED ANODES WHT SIGNAL...

Страница 10: ...5 14 15 16 10 13 7 3 9 1 2 3 4 6 9 12 5 8 11 25 56 49 55 51 30 37 38 39 1 1 2 2 2 2 USE TRIBOLUBE 23 USE PERMABOND LM113 OR LOCTITE 222 USE PARKER O LUBE ON ALL O RINGS AND ALL MATING SURFACES ASSEMBL...

Страница 11: ...late 744388 1 ITEM NO DESCRIPTION PART NUMBER QUANTITY 36 Planet Gear 718165 9 37 Speed Reducer Housing 120414 1 38 Motor Face Plate 745165 1 39 Socket Head Screw 765052 8 40 Motor Assembly 24 volt 88...

Страница 12: ...se maintenance or storage negligence of the owner or user repair or modification after delivery damage failure to follow our instructions or recommendations or anything else beyond our control WE MAKE...

Отзывы: