Akron Brass Style 8840 Скачать руководство пользователя страница 6

6

Troubleshooting

 

•  Switch source voltage is not close to incoming system voltage (within 1-2 volts) 

 

 

1.  Switch source voltage may be shorted to ground either directly or indirectly.  Remove the cable from 

 

 

 

the TANK FILL VALVE SWITCHES Connector and check the voltage again.  If the voltage is still incorrect, 

 

 

 

remove the cable from the INPUT SWITCHES AND COUNTER Connector and check the voltage again.  

 

 

 

If the voltage is still incorrect, remove the cable from the PRESSURE TRANSDUCER Connector and 

 

 

 

check the voltage again.  If it is still incorrect, replace the circuit board.

 

 

2.  If unplugging one of the cables corrected the voltage reading, then trace out the wiring for that cable and 

 

 

 

attempt to find the short circuit.  If the cable from the TANK FILL VALVE SWITCHES Connector seems to 

 

 

 

be at fault, also check to make sure that the wires inside the logic box between the TANK FILL VALVE 

 

 

 

SWITCHES Connector and terminal block TB3 are wired Correctly

 

 

•  “Opened” switch does not appear to be working

 

 

1.  Check the wiring to make sure that voltage is going out to the switch and that the return from the switch 

 

 

 

is going into terminal TB3-27.  Make sure that the wiring has not been crossed with the “Closed” switch 

 

 

 

wiring, either in the external cable or in the logic box.

 

 

2.  Make sure that the switch is being activated by the sector gear.

 

•  “Closed” switch does not appear to be working

 

 

1.  Check the wiring to make sure that voltage is going out to the switch and that the return from the switch 

 

 

 

is going into terminal TB3-26.  Make sure that the wiring has not been crossed with the “Opened” switch 

 

 

 

wiring, either in the external cable or in the logic box.

 

 

2.  Make sure that the switch is being activated by the sector gear.

MAINTENANCE

After 80,000 cycles or every 56 weeks, whichever comes first, the following Maintenance needs to be performed:
An Akron Style 9167 must be used to rebuild the valve.  Complete instructions are included with each kit.

WARRANTY

All components of the Hi Cycle Valve carry a one (1) year Akron Brass warranty provided the maintenance instructions outlined above are followed.

Содержание Style 8840

Страница 1: ...dy 2 The actuators can be mounted in one of four positions 3 Keep the piping aligned so undue stresses are not placed on the valve Victaulic connections in lieu of pipe threads do help 4 Be sure the w...

Страница 2: ...he tank is above the set point the controller moves the motorized valve in the closed direction As long as the water level stays above the set point the controller continues to close the valve until a...

Страница 3: ...of the valve External LEDs can be plugged into the logic box at the LEDs connector and will duplicate the function of the on board LEDs The current limiting resistors are built onto the board so ordin...

Страница 4: ...the Transducer connector is correctly mated with its receptacle 4 Replace the pressure transducer if the problem persists Tank Fill Valve Does Not Open Tank Remains Empty 1 Make sure the Tank Fill Val...

Страница 5: ...When the Opened switch is activated by the sector gear the LED will blink slowly at once a second Normally the valve will stay in this position but after 5 seconds the valve may open to the hard stop...

Страница 6: ...tly Opened switch does not appear to be working 1 Check the wiring to make sure that voltage is going out to the switch and that the return from the switch is going into terminal TB3 27 Make sure that...

Страница 7: ...B B A B C A B C VIEW B B TYPICAL 1 SEALING PLUG GND POWER A B C A B C VIEW C C TYPICAL 3 SEALING PLUG OPEN VALVE CLOSE 3 POSITION DEUTSCH 2 POSITION DEUTSCH 5 POSITION DEUTSCH SYSTEM VDC SYSTEM VDC S...

Страница 8: ...CHES 4 POSITION DEUTSCH 1 2 4 3 SYSTEM VDC CLOSED OPENED SYSTEM VDC CONNECTOR DTM06 4S E007 SOCKET 0462 201 20141 WEDGE LOCK WM 4S A B C D E A B C D E GREEN RED VIEW D D TYPICAL 1 WHITE BLACK DRAIN PR...

Страница 9: ...TATION GRN SIGNAL ALGORITHM SELECTOR JUMPER WHITE OUT TO NO VOLTAGE COUNTER GRY OUT TO NO VOLTAGE COUNTER GRY VEHICLE GROUND BLK SYSTEM VDC VEHICLE BATTERY RED SYSTEM VDC OUT TO LED ANODES WHT SIGNAL...

Страница 10: ...5 14 15 16 10 13 7 3 9 1 2 3 4 6 9 12 5 8 11 25 56 49 55 51 30 37 38 39 1 1 2 2 2 2 USE TRIBOLUBE 23 USE PERMABOND LM113 OR LOCTITE 222 USE PARKER O LUBE ON ALL O RINGS AND ALL MATING SURFACES ASSEMBL...

Страница 11: ...late 744388 1 ITEM NO DESCRIPTION PART NUMBER QUANTITY 36 Planet Gear 718165 9 37 Speed Reducer Housing 120414 1 38 Motor Face Plate 745165 1 39 Socket Head Screw 765052 8 40 Motor Assembly 24 volt 88...

Страница 12: ...se maintenance or storage negligence of the owner or user repair or modification after delivery damage failure to follow our instructions or recommendations or anything else beyond our control WE MAKE...

Отзывы: