background image

Page | 3 

 

 

5 SYSTEM INSTALLATION  

The Navigator Pro controller can be installed in a number of different system configurations and has been designed 
to provide the installer with flexibility during installation. This retrofit kit is intended to work with one display 
connected directly to one valve and includes a 10’ wiring harness.  If a different configuration or harness length is 
needed, such as an instance where there is an auxiliary controller, components should be purchased separately.  
Harnesses can also be made using standard Deutsch connectors and the pin-out information in the ELECTRICAL 
INSTALLATION section of the 9333 or 9335 manual. 

 

5.1 ELECTRICAL INSTALLATION 

The retrofit kit includes the extension harness for the motor that allows it to plug into the motor driver, as well as 
the 10’ harness that runs between the motor driver and the valve controller/display.  If the 9335 retrofit kit is used, 
additional adapter harnesses may need to be ordered for the flow sensor or pressure transducer (refer to the wiring 
harnesses and components chart at the end of the instructions).  The only modification that will need to be made to 
the existing wiring is changing the plug that is supplying power to the existing valve controller. 

 

5.2 MECHANICAL INSTALLATION 

The 9333/9335 valve controller display will fit the existing panel cutout and mounting holes from the 9303 or 
9313/9315 and is attached to the panel using four 10-24 socket-head cap-screws. An installation torque of 6-8 in-lbs 
should be applied when installing the valve controller display to prevent damage to the enclosure.  The motor driver 
replaces the existing black plastic cover on top of the electric actuator using the existing mounting hardware. 

 

 

 
 

Содержание 9333

Страница 1: ...TOOLS REQUIRED 2 3 PRODUCT RATINGS 2 4 OVERVIEW 2 5 SYSTEM INSTALLATION 3 5 1 ELECTRICAL INSTALLATION 3 5 2 MECHANICAL INSTALLATION 3 6 INITIAL SETUP FOR A NEW SYSTEM MINIMUM SETUP 3 6 1 ASSIGNING A VALVE 4 6 2 CALIBRATING VALVE POSITION 4 7 OPERATIONAL FEATURES 5 7 1 Opening and closing the valve 5 ...

Страница 2: ... depends on valve type Weight 3 lbs 14 kg Operating Temperature 40 C 70 C Storage Temperature 40 C 85 C Ingress protection IP67 equivalent J1939 CAN networked 4 OVERVIEW The Style 9333 9335 Navigator Pro controller allows the user to control an Akron Brass electric valve It is designed to be used with an Akron Brass Swing Out valve only The Style 9333 9335 is a display interface only and does not ...

Страница 3: ...into the motor driver as well as the 10 harness that runs between the motor driver and the valve controller display If the 9335 retrofit kit is used additional adapter harnesses may need to be ordered for the flow sensor or pressure transducer refer to the wiring harnesses and components chart at the end of the instructions The only modification that will need to be made to the existing wiring is ...

Страница 4: ...to controller connection the display will automatically be assigned to the valve For a different system configuration refer to the Installation Operating Manual for the appropriate valve controller If the display and motor driver are not already assigned they will request that when they are powered up together for the first time When the assignment process begins either at startup or through the S...

Страница 5: ...ensor After calibration is complete press the OK button to return to the Valve Setup screen 7 OPERATIONAL FEATURES The Style 9333 9335 Navigator Pro Controller has been designed to be intuitive and easy to use Once configured the operation is simple Basic operation of the controller is described below 7 1 Opening and closing the valve To open the valve using the Navigator Pro press the GREEN butto...