Version : 2014.2
3
Specific Operating Instructions
-EN-
1
Earth connection
2
Fence connection
3 Earth electrode
4 ON / OFF switch
5 Indicator light
6 Drilled hole for 12V cable
a.) Installation
Assemble the earth electrode (3) as shown in the above figure; screw the earth connecting cable (7) onto the
earth electrode with the fastening screw. Drive the earth electrode into the ground as far as the angle brackets
and then place the appliance in upright position in the screwed-on angle brackets, see above figure.
b.) Functional description of the appliance
Open the appliance by pressing the catch hook on both sides and simultaneously raising the lid. Insert the
battery into the receptable and connect to the appliance. Close the lid. Operate the appliance only in vertical
position and with the catch hook clicked firmly into place. Put the appliance into service
without
fence and
earth. If the indicator light (5) flashes green, the appliance is ready for use. If it flashes red, check the 9V
battery for correct voltage (min. 6V). If the indicator light does not
flash, check the battery for correct polarity or
have the appliance checked by a technician.
c.) Functional description with connected fence system ( fence + earth )
Indicator light (5): flashes green to indicate the fence condition or red to indicate the 9V battery
condition
Flashes
green
Flashes
red
Audible
clicks
Output voltage
9V battery
1
YES
NO
YES
> 2500 V
= minimum requirement
OK
(>6V)
2
NO NO
YES
< 2500
see fault finding in enclosed instruction manual
(Figure 2; p.5)
OK
(>6V)
3
YES
YES
YES
> 2500 V
=
minimum requirement and:
Replace as soon
as possible
4
NO
YES YES
< 2500 V
(Figure 2; S.5)
and:
Replace as soon
as possible
5
NO
YES
NO
No pulses
Replace at once
6
NO NO NO
see b.) Functional description of the appliance, without fence and earth
If the control lamp (5) should blink faster than 1x per second, the device must be switched off immediately and
inspected by a specialty technician before re-commissioning.
The device provides 12v operation with total discharge protection. This is indicated by red blinking of the pilot
lamp.
The 12V accumulator voltage should therefore be checked at regular intervals with a highly accurate
measuring instrument (see battery and accumulator maintenance in the enclosed instruction manual). The
appliance can also be operated with a solar kit obtainable through specialised dealers.
This equipment carries a 3-year warranty in accordance with our Warranty Terms & Conditions!
Please see the attached Operating Instructions for safety tips, earthing, commissioning, maintenance
of battery and accumulator, warranty terms and conditions and potential sources of fault!
SERVICE Addresses:
Please contact your specialist dealer
Normal operation with 9V dry battery; alternatively, the appliance can be
operated with a 12V wet accumulator!
Not suited for use in barns!
2
1
3
4
6
5
7
Содержание BA-1061
Страница 1: ...BA 1061 ...
Страница 24: ......