[Data
R/W]
Click the [Data R/W] button in the main window for data read/write dialog box.
Data write is available to specified address.
Figure 8. Window of [ Data R/W ]
Address Box : Input data address in hexadecimal numbers for data writing.
Data Box : Input data in hexadecimal numbers.
Mask Box : Input mask data in hexadecimal numbers.
This is “AND” processed input data.
[Write] : Writing to the address specified by “Address” box.
[Close] : Closing the dialog box and finish the process.
Data writing can be cancelled by this button instead of [Write] button.
*The register map will be updated after executing [Write] or [Read] commands.