akira CT-25NI9AN Скачать руководство пользователя страница 9

 

 

                                              

 

 

Model No: CT-25NI9A

N

   

                                           

Version 1.0 

 

   

 

 

 

 

 

9

6. Two different initializing 

a)  Fully initialize: initialize the EEPROM's most work data and preset default value. In-
cluding:   
    work parameter of NN5199, horizontal and vertical parameter, OPTION parameter   
    (via. function set parameter), picture mode parameter, volume mode parameter and white 
    balance parameter. 
b)  Partially initialize: only initialize work parameter of NN5199 and the ninth digital and the 
tenth digital of function set parameter(via. ISUD0, ISUD1,ISUD3,ISUD4,ISUD5),preset as 
interior values. 

 
 
7. If use 25” or above Pure Flat tube, adjustment of horizontal size and pincushion distortion must be 

done as follows : 

a)  Receive 60dBuV PAL system monoscope pattern; 
b)  Press 'factory' key one time and go to system parameter adjustment menu; 
c)  Press 'MENU' key and select ' Position Menu ' as below 

 

V POSITION   

for adjust vertical position   

00 to 07   

 

H POSITION   

for adjust Horizontal position   

00 to 1F   

 

V EHT        

for adjust vertical shape   

00 to 0F   

 

H EHT        

for adjust Horizontal shape   

00 to 0F 

   

d)  Press 'MENU' key and select ' geometry Menu ' as below; 

   

V-AMP    

for adjust vertical size         

00 to 7F 

 

V_LINE    

for adjust vertical linearity      

00 to 3F   

 

V_SC3    

for adjust vertical S-correction X

  00 to 3F     

 

H-AMP    

for adjust Horizontal size       

00 to 3F   

 

EW-PARA   

for adjust Pincushion          

00 to 3F   

 

EW-COR   

for adjust Pincushion corner    

00 to 0F   

 

TRAPEZ     

for adjust trapezium          

00 to 3F   

 

V_SC5    

for adjust vertical S-correction X

5

    00 to 0F 

 

   

e)  Receive 60dBuV NTSC system monoscope pattern; 

         Repeat the above step 7.2 to 7.4. 

f)  Exit system parameter adjustment menu by pressing 'factory' key twin. 
 

 
8. Option Code 
 

1. Press 'factory' key twin and go to Option Code Menu 

 

     The first digit 8 Digit is set by Factory. The last two digit “9” and “A” is the random data from 
NN5198/NN5199.   
 
 
 
 
 
 
 
 

 

1 2 3 4 5 6 7 8 

9 A 

1 3 7 1 4 0 4 6 

* *  

 

Содержание CT-25NI9AN

Страница 1: ...C C Co o ol l lo o ou u ur r r T T TV V V S S Se e er r rv v vi i ic c ce e e M M Ma a an n nu u ua a al l l...

Страница 2: ...Model No CT 25NI9AN Version 1 0 2 CHASSIS 5N11 MODEL CT 25NI9AN...

Страница 3: ...Model No CT 25NI9AN Version 1 0 3 CONTENTS 1 SPECIFICATIONS 4 2 X RAY RADIATION PRECAUTION 5 3 SAFETY PRECAUTION 5 4 PRODUCT SAFETY NOTICE 5 5 ALIGNMENT INSTRUCTION 6 6 SCHEMATIC DIAGRAM 14...

Страница 4: ...Picture Tube 64 cm 25 diagonal Ext Antenna 75 Ohm Coaxial Cable Ext In Out Audio Video in out Speakers 8W x 2 Volts A AC100 260V 50 60Hz R N CP AC 150 260V 50 60Hz Power Consumption 25 120W Dimension...

Страница 5: ...after referring to the Product Safety Notice SAFETY PRECAUTION Warning Service should not be attempted by anyone unfamiliar with necessary precaution on this receiver The following are the necessary...

Страница 6: ...L key and VOL key on the control board at the same time and switch on power switch then go to the function set menu After TV is on press factory key See Note 1 twin then go to the function set menu 1...

Страница 7: ...ance test signal b Set picture MILD mode c Insert the special plug into CN002 press adjustment key which belongs to white balance adjustment equipment and go to auto white balance adjustment d After a...

Страница 8: ...itialized with default data after main power switch is on Most parameters are free alignment after initialized only need adjust the several parameters of function set parameter and system parameter ad...

Страница 9: ...and select Position Menu as below V POSITION for adjust vertical position 00 to 07 H POSITION for adjust Horizontal position 00 to 1F V EHT for adjust vertical shape 00 to 0F H EHT for adjust Horizont...

Страница 10: ...e zero M decoder ON OFF I decoder ON OFF BG decoder ON OFF Reserved for internal using must be zero OPTION 3 Sopdata3 x x x x x x x x Tuner LNA Hold on when no signal VIF VCO 38MHz or 38 9MHz selectio...

Страница 11: ...tion yoke and pull the deflection yoke towards you 7 Enter into ADJUST MENU set the values of C R C G C B to 00 8 Adjust the purity magnets so that green field is obtained at the center of the screen...

Страница 12: ...Receive colour pattern signal and the system colour PAL SECAM NTSC Check the power main on off switch brightness volume colour contrast and tint The picture quality must not have colour noise unbalan...

Страница 13: ...HIGH POTENTIAL TESTING 1 Set the mega meter is set in position Insulation tester 2 Set the meter to DC500V 3 Use the meter probe onto the tuner body and the power cord on connector socket 4 Switch on...

Страница 14: ...0 0 1 0 0 1 1 2 0 3 3 4 5 1 1 4 4 0 6 6 6 6 00 00 1 23 45 00 00 55 55 16 74 14 38 79 2 0 4 38 38 38 14 1 14 74 12 2 2 2 2...

Отзывы: