akira CT-25NI9AN Скачать руководство пользователя страница 12

 

 

                                              

 

 

Model No: CT-25NI9A

N

                                           

Version 1.0 

 

   

 

 

 

 

 

12 

                                  Purity Magnet
                 RB-G     RB
                   
Magnet Clamper

              Static Magnet

 

(FIG.1) 

 
 
 
 
 

(IV)  FINAL INSPECTION AND ELECTRICAL FUNCTIONAL CHECK 

 

1. CHECKING THE ELECTRICAL FUNCTION:- 

1.  Connect the power cord and connect the signal to RF input. 
2.  Check the power supply whether OK or not. Switch on the TV set and the LED is on. 

Switch off the TV screen and should not have CRT spot within 3 sec. 

3.  Receive the channel 1 for monoscope pattern to check the picture focus and the round 

circle should not be distorted. The centre position, and VOS line/size are within spec. 
Check the brightness, contrast and colour condition. Check the convergence, picture 
must be clear, focus OK and white balance are OK. Also check the complete screen 
picture quality. High voltage condition OK and the Screen picture must be OK. 

4.  Check all the functional keys must be working well. 
5.  Receive colour pattern signal and the system colour. (PAL/SECAM/NTSC). Check 

the power main on/off switch, brightness, volume, colour, contrast and tint. The 
picture quality must not have colour noise, unbalance size and distorted condition. 

6.  Check the sound quality standards, Volume up/down are OK to spec, and sound 

output. Ensure the sound output is not distorted and noisy. No interference for 
DK/BG/I/M. 

7.  Use remote Control Unit for all types of function check and ensure OK. 
8.  Check the words display condition. 
9.  Shock test and make sure the picture and sound are not distorted and shifted. 
10.  Use strong and weak signal to check the colour picture condition. After adjust the 

signal level to 35-40 dB and the colour should not gone. The picture and sound must 
be OK. At 60 dB the picture should not have snow noise.   

11.  Ensure the factory mode setting are set. Set-off the factory mode function and last 

switch off the TV set. 

12.  All the “NG” sets must send for repairing and recording for reference. 
13.  Check the AV input and output the picture and sound must be OK. 
 

 
 
 

Содержание CT-25NI9AN

Страница 1: ...C C Co o ol l lo o ou u ur r r T T TV V V S S Se e er r rv v vi i ic c ce e e M M Ma a an n nu u ua a al l l...

Страница 2: ...Model No CT 25NI9AN Version 1 0 2 CHASSIS 5N11 MODEL CT 25NI9AN...

Страница 3: ...Model No CT 25NI9AN Version 1 0 3 CONTENTS 1 SPECIFICATIONS 4 2 X RAY RADIATION PRECAUTION 5 3 SAFETY PRECAUTION 5 4 PRODUCT SAFETY NOTICE 5 5 ALIGNMENT INSTRUCTION 6 6 SCHEMATIC DIAGRAM 14...

Страница 4: ...Picture Tube 64 cm 25 diagonal Ext Antenna 75 Ohm Coaxial Cable Ext In Out Audio Video in out Speakers 8W x 2 Volts A AC100 260V 50 60Hz R N CP AC 150 260V 50 60Hz Power Consumption 25 120W Dimension...

Страница 5: ...after referring to the Product Safety Notice SAFETY PRECAUTION Warning Service should not be attempted by anyone unfamiliar with necessary precaution on this receiver The following are the necessary...

Страница 6: ...L key and VOL key on the control board at the same time and switch on power switch then go to the function set menu After TV is on press factory key See Note 1 twin then go to the function set menu 1...

Страница 7: ...ance test signal b Set picture MILD mode c Insert the special plug into CN002 press adjustment key which belongs to white balance adjustment equipment and go to auto white balance adjustment d After a...

Страница 8: ...itialized with default data after main power switch is on Most parameters are free alignment after initialized only need adjust the several parameters of function set parameter and system parameter ad...

Страница 9: ...and select Position Menu as below V POSITION for adjust vertical position 00 to 07 H POSITION for adjust Horizontal position 00 to 1F V EHT for adjust vertical shape 00 to 0F H EHT for adjust Horizont...

Страница 10: ...e zero M decoder ON OFF I decoder ON OFF BG decoder ON OFF Reserved for internal using must be zero OPTION 3 Sopdata3 x x x x x x x x Tuner LNA Hold on when no signal VIF VCO 38MHz or 38 9MHz selectio...

Страница 11: ...tion yoke and pull the deflection yoke towards you 7 Enter into ADJUST MENU set the values of C R C G C B to 00 8 Adjust the purity magnets so that green field is obtained at the center of the screen...

Страница 12: ...Receive colour pattern signal and the system colour PAL SECAM NTSC Check the power main on off switch brightness volume colour contrast and tint The picture quality must not have colour noise unbalan...

Страница 13: ...HIGH POTENTIAL TESTING 1 Set the mega meter is set in position Insulation tester 2 Set the meter to DC500V 3 Use the meter probe onto the tuner body and the power cord on connector socket 4 Switch on...

Страница 14: ...0 0 1 0 0 1 1 2 0 3 3 4 5 1 1 4 4 0 6 6 6 6 00 00 1 23 45 00 00 55 55 16 74 14 38 79 2 0 4 38 38 38 14 1 14 74 12 2 2 2 2...

Отзывы: