background image

 

 
 

Model No: CT-14DX9A_14DX9N_14DX9R_14DX9CP_14DX9R(G)_14DX9(IKD)                                           
Version 1.0

 

7

 

 

4. 

B+ Voltage Alignment

:- 

4.1.  Set and connected all the points. 

4.2.  Locate the RP551 alignment VR location. 

4.3.  Use digital multi-meter to measure the B+ voltage. 

4.4.  Switch on the TV chassis and connect by Philips pattern for alignment. 

4.5.  Align the Rp551 VR with the digital multi-meter to the required spec voltage110 Volt  +/-

0.5V,(14”&21”) and 129.5Volt +/- 0.5V (25”/29”/34”). 

4.6.  Alignment finished, apply glue onto RP551 VR. After glue re-check the B+ voltage to ensure 

the B+ voltage is within spec of 110V(14”&21”) and 129.5Volt(25”/29”/34”). 

 

5. 

Alignment Mode and Factory Setting

:- 

5.1.  Switch on the TV chassis and change to AV mode position. 

5.2.  Press “Factory mode” key to enter “ factory alignment mode”. Use “CH +/-“ to select the 

alignment item, and use “V +/-“ keys to do adjustment to you requirement. 

 

6. 

IF Voltage Adjustment

:- 

6.1.  Setting-up – set-up the Philips 5418/5518 pattern generator, AV out frequency to 38MHz, 

signal level to 70dB +/- 2 dB. 

6.2.  IF set-up 38MHz signal connected with coaxial cable with 1 capacitor of “0.01uF” and 

connect to main chassis IF” / ground points. 

6.3.  Tuner must not insert with the antenna. 

6.4.  Switch on TV chassis, adjust the IF coil “T110” and check the Ch 2 brightness line for the 

range change from 0 to 5V. Readjust the voltage to meet Ch 1 position. 

 

Note: LA76810A alignment only on VCO (T110) not others. 

 

7. 

Vertical Line – Pin–Cushion Adjustment

 :- 

7.1.  Receive Channel 7 colour bar.Adjust the PR301 for vertical lines pin-cushion to 1 straight 

line, adjust the PR302 for horizontal phase to spec requirement. 

 

8. 

Vertical Line and Size Adjustment

:- 

8.1.   Receive crosshatch pattern, use factory mode remote control to press “factory mode”  key 

for adjustment. Using CH +/- keys for V. Size and V. Line selection. 

8.2.   Use V +/- keys to adjust the picture line requirement and the size to spec. 

 

9. 

RF AGC Adjustment

:- 

9.1.  Receive channel 13 of picture pattern. Adjust the AGC at 60 dB for no picture noise. 100 dB 

– picture should not be distorted and the VOS do not have unstable condition. 

 

10. 

Checking the Electrical Function

:- 

10.1. Connect the power cord and connect the signal to RF input. 

10.2. Check the power supply whether OK or not. Switch on the TV set and the LED is on. Switch 

off the TV screen and should not have CRT spot within 3 sec. 

10.3. Receive the channel 1 for monoscope pattern to check the picture focus and the round circle 

should not be distorted. The Centre position, and VOS line/size are within spec. Check the 

brightness, contrast and colour condition. Check the convergence, picture must be clear, 

focus OK and white balance are OK. Also check the complete screen picture quality. High 

voltage condition OK and the Screen picture must be OK. 

10.4. Check all the functional keys must be working well. 

10.5. Receive colour pattern signal and the system colour. (PAL/SECAM/NTSC) Check the power 

main on/off switch, brightness, volume, colour, contrast and tint. The picture quality must not 

have colour noise, unbalance size and distorted condition. 

10.6. Check the sound quality standards, Volume up/down are OK to spec, and sound output. 

Ensure the sound output is not distorted and noisy. No interference for DK/BG/I/M. 

10.7. Use remote Control Unit for all types of function check and ensure OK. 

10.8. Check the words display condition. 

10.9. Shock test and make sure the picture and sound are not distorted and shifted. 

 

Содержание CT-14DX9

Страница 1: ...C C Co o ol l lo o ou u ur r r T T TV V V S S Se e er r rv v vi i ic c ce e e M M Ma a an n nu u ua a al l l ...

Страница 2: ...9N_14DX9R_14DX9CP_14DX9R G _14DX9 IKD Version 1 0 2 M M Mo o od d de e el l l G G Gr r ro o ou u up p p C C CT T T 1 1 14 4 4D D DX X X9 9 9 CHASSIS SS1 MODEL CT 14DX9A CT 14DX9N CT 14DX9R CT 14DX9CP CT 14DX9R G CT 14DX9 IKD ...

Страница 3: ...CT 14DX9A_14DX9N_14DX9R_14DX9CP_14DX9R G _14DX9 IKD Version 1 0 3 CONTENTS Specifications 4 X Ray Radiation Precaution 5 Safety Precaution 5 Product Safety Notice 5 Alignment Instructions 6 Schematic Diagram 12 ...

Страница 4: ...PAL NTSC P B Picture Tube 14 37 diagonal Ext Antenna 75 Ohm Coaxial Cable Ext In Out Audio Video in out Speakers 8W x 2 Audio Output Maximum 4W Volts A AC100 260V 50 60Hz R N CP AC150 260V 50 60Hz Power Consumption 14 65W Dimension 14 401 W x 365 D x 345 H mm Net Weigh 14 10 kg REMOTE CONTROL Transmitting System Infra red Power Supply DC 3V 1 5Vx2 Design and specifications are subject to change wi...

Страница 5: ...d during any dynamic service to avoid possible shock hazard 2 Always discharge the picture tube anode to the CRT conductive coating before handling the picture tube The picture tube is highly evacuated and if broken glass fragment will be violently expelled Use shatter proof goggles and keep picture tube away from the unprotected body while handling 3 When replacing a chassis in the cabinet always...

Страница 6: ...pes 1 4 Digital multi meter with LED display 4 digits 1 5 Factory mode remote control unit 2 Channels setting required Channel 1 Monoscope pattern PAL DK Music Channel 7 Half Colour Bar pattern PAL I Modulation Channel 12 Crosshatch pattern PAL BG Music Channel 13 Picture PAL DK Music Channel 24 Half Colour Bar pattern PAL BG Modulation Channel 56 Full Colour Bar pattern NTSC Modulation 3 Set up A...

Страница 7: ...ical Line and Size Adjustment 8 1 Receive crosshatch pattern use factory mode remote control to press factory mode key for adjustment Using CH keys for V Size and V Line selection 8 2 Use V keys to adjust the picture line requirement and the size to spec 9 RF AGC Adjustment 9 1 Receive channel 13 of picture pattern Adjust the AGC at 60 dB for no picture noise 100 dB picture should not be distorted...

Страница 8: ...h Potential Testing 13 1 Set the mega meter is set in position Insulation tester 13 2 Set the meter to DC500V 13 3 Use the meter probe onto the tuner body and the power cord on connector socket 13 4 Switch on the button and test the insulation performance and the reading at 2 3 position 13 5 Insulation spec must over 9 0 Mohm if not reject Note Everyday work check the high pot Condition as 3100V 1...

Страница 9: ...and you can use P P key and V V key for selection and adjustment 1 Setting of company logo 1 1 Switch on the TV set and set the TV in AV mode Press Remote control DISP key and the TV screen will display AV and follow by presetting the Numeric key 6 4 8 3 to enter the company logo setting 1 2 Press the P P key for selection of function and press V V key for adjustment Press key to change or select ...

Страница 10: ...3 16 14 0 31 06 V POSI Vertical position 24 23 23 25 0 63 07 V SC Vertical SC adjust 0 0 0 0 31 08 NT V SIZE NTSC Vertical size 6 0 0 0 31 32 09 NT V LINE NTSC Vertical line 1 0 0 0 15 16 10 NT V POST NTSC Vertical position 10 0 0 0 31 32 11 NT V SC NTSC Vertical SC 2 0 0 0 15 16 12 RF AGC RF AGC adjustment 23 26 26 26 0 63 13 VOLUME OUT Sound output 128 108 108 108 0 127 14 SUB CONT Contrast 23 2...

Страница 11: ... 0 7 16 VOL FIL Sound trap filter control 1 1 1 0 3 17 VIF SYS SW VCO setting 1 0 0 0 0 7 18 VIDEO LEVEL Video output adjustment 7 7 7 0 7 19 FM LEVEL Sound output adjustment 16 16 16 0 31 20 POWER OPTION Power on selection 0 1 1 1 0 3 21 LOGO AT P ON Logo display 1 1 1 0 1 22 SEARCH CHECK Check the auto search function 1 1 1 0 1 23 BAND OPTION Band selection 0 0 0 0 3 24 CHANNEL MAX Maximum chann...

Страница 12: ......

Отзывы: