No Description 

Part 

No 

Qty 

1 Front 

Grill 

22413431 

2 Nut 

M6 

70310132 

3 Washer 

70410252 

Axial Flow Fan 

10333412 

5 Front 

Plate 

01533428 

6 Metal 

Base 

01203030 

7 4-way 

Valve 

8 Capillary 

Assy 

03003030 

9 Compressor 

RH207VHKC  00120082 

10 

Nut with Washer M8 

70310014 

11 Handle 

26233431 

12 Valve 

1/2" 

07100147 

13 Valve 

1/4" 

07100120 

14 Valve 

Support 

01713424 

15 

Right Side Plate Assy 

01302000 

16 Wire 

Clamp 

71010103 

17 Insulation 

Gasket 

70410525 

18 

Terminal Board T386A 

42011241 

19 Electric 

Plate 

01413425 

20 Comp 

Capacitor 

30uF/450V  33000021 

21 Capacitor 

clamp 

02143401 

22 

Fan Capacitor 3uF/450V 

33010027 

23 

Terminal Board 2-8 

24 

Isolation Sheet Assy 

01233417 

25 Tube 

Sensor 

26 Condenser 

Assy 

01103408 

27 

Rear grill Assy 

11123402 

28 

Top cover Assy 

01253261 

29 Motor 

Support 

01703391 

30 Self-tapping 

Screw 

10140165 

31 Motor 

FW48A 

15013036 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

CIRCUIT DIAGRAM 

 

These circuit diagrams are subject to change without notice. 
Please refer to the ones stuck on the machines. 

 

                                               

 
 
Model  No: AC-S13CGx2.doc 

                                            

Version 1.0 
 

   

 

 

 

 

 

Содержание AC-S13CG series

Страница 1: ...A A Ai i ir r r C C Co o on n nd d di i it t ti i io o on n ne e er r r S S Se e er r rv v vi i ic c ce e e M M Ma a an n nu u ua a al l l ...

Страница 2: ...2 Model No AC S13CGx2 doc 3 Model AC S13CG x 2 Version 1 0 ...

Страница 3: ... Outline dimension of outdoor unit 11 Exploded view of indoor unit 12 Spare parts list of indoor unit 13 Exploded view of outdoor unit 14 Spare parts list of outdoor unit 15 Circuit Diagram 16 PCB Function Manual 17 TECHNICAL SPECIFICATION Content AC S13CG Model No AC S13CGx2 doc Version 1 0 ...

Страница 4: ...Indoor unit Net weight Kg 8 5 Input power W 1179 Current A 5 33 L R A A 29 Throttling method Capillary Compressor RH207VHKC Starting method Capacitor Starting Working temp 115o C 115o C Condenser Aluminum fan copper tube Pipe diameter 9 52 Row fin distance mm 1 1 6 Working area 0 4 Fan motor speed rpm 48 880 Type piece Axial fan 1 Diameter mm 400 Defrosting method Auto defrost Noise dB A 56 Dimens...

Страница 5: ...5 Cooling operation condition In testing indoor and outdoor have same work condition Heating operation Indoor work condition dry bulb temp 21 wet bulb temp 15 5 o C Model No AC S13CGx2 doc Version 1 0 ...

Страница 6: ...6 Model No AC S13CGx2 doc Version 1 0 ...

Страница 7: ...7 Model No AC S13CGx2 doc Version 1 0 ...

Страница 8: ...8 Model No AC S13CGx2 doc Version 1 0 ...

Страница 9: ...9 Model No AC S13CGx2 doc Version 1 0 ...

Страница 10: ...10 OUTLINES AND DIMENSIONS OF INDOOR UNIT Model No AC S13CGx2 doc Version 1 0 ...

Страница 11: ...11 OUTLINES AND DIMENSIONS OF OUTDOOR UNIT Model No AC S13CGx2 doc EXPLODED VIEW OF INDOOR UNIT Version 1 0 ...

Страница 12: ...12 Model No AC S13CGx2 doc Version 1 0 ...

Страница 13: ...012002 1 21 Guide Louver 10512001 1 22 Remote Controller 30512505 1 23 Guide Louver Bearing 10542011 3 24 Air Cleaner B 11012003 1 25 Evaporator Pipe Cover 06122001 1 26 Sensor Insert 42020063 1 27 Stepping Motor MP24GA 15212102 1 28 Motor FN14A 15012108 1 29 Motor Clamp 26112014 1 30 Wire Clamp 71010103 1 31 Pipe Clamp 24242001 1 32 PCB 5K512 30025507 1 33 Tube Sensor 39000165 1 34 Room Sensor 39...

Страница 14: ...14 PARTS LIST OF OUTDOOR UNIT Model No AC S13CGx2 doc Version 1 0 ...

Страница 15: ...Clamp 71010103 2 17 Insulation Gasket 70410525 1 18 Terminal Board T386A 42011241 1 19 Electric Plate 01413425 1 20 Comp Capacitor 30uF 450V 33000021 1 21 Capacitor clamp 02143401 1 22 Fan Capacitor 3uF 450V 33010027 1 23 Terminal Board 2 8 1 24 Isolation Sheet Assy 01233417 1 25 Tube Sensor 1 26 Condenser Assy 01103408 1 27 Rear grill Assy 11123402 1 28 Top cover Assy 01253261 1 29 Motor Support ...

Страница 16: ...16 PCB FUNCTION MANUAL 3 In 1 PCB Function manual A Running mode Model No AC S13CGx2 doc Version 1 0 ...

Страница 17: ...ion a Anti freezing function i If compressor have run 6 minutes and detect T eva 0o C for continuous 3 min utes then the compressor outdoor fan stopped indoor fan run at the set fan speed After 3 minutes later it will run at the original state if T eva or 10o C b Compressor protection i Compressor s starting interval should be more than 3 minutes no matter in what ever modes and conditions If it s...

Страница 18: ...ing range is 16 30o C 3 The working conditions of auxiliary electric heater a In heating mode when compressor is working indoor motor runs at high speed and middle speed If it detect T eva 50o C for continuous 8 seconds and T indoor or 25o C electric heater will work if compressor stop or indoor motor runs at low speed or T eva 54o C or T indoor 28o C or 10 seconds before defrosting the electric h...

Страница 19: ...O mode 1 In AUTO mode standard cooling T set 25o C standard heating T set 20o C 2 Working procedures a If T indoor or T set 1o C select cooling mode from this time the set temp is 25o C If T indoor or T set 1o C compressor and outdoor motor stop indoor mo tor runs at the set speed if T set 1 T indoor T set 1o C keep the original state b If T indoor or T set 2o C select heating mode from this time ...

Страница 20: ...ir 1 ii Press the button AIR on the remote controller to select fresh air 1 function the swing motor keeps running till you give a signal to change it 6 Automatic fan speed a In cooling mode if T indoor T set 5o C high speed T indoor or T set 3o C middle speed T indoor or T set 1o C low speed b In dehumidify mode if T indoor or T set 5o C high speed T indoor or T set 2o C low speed SLEEP mode 1 In...

Страница 21: ......

Отзывы: