OPERATING MANUAL
14 (112)
Document-ID: 947422-000 Multi
Version: C0
EN
13 OUTPUT CONFIGURATION
Each of the 6 outputs in the receiver can be configured as either momentary or remaining
(latched) using a special configuration mode.
Note!
The transmitter/s and receiver must be paired before output configuration can be done,
Caution.
All outputs must be disabled before configuration by disconnecting the
Output Power Input (SW) terminal (see fig. 3)
.
13.1
To configure the receiver outputs do the following:
1.
Power off the receiver (if you have a conversion box for 230 V AC wait 10
seconds).
2.
Disconnect the Output Power Input terminal, see figure 3.
3.
Place the jumper in the J1(left) position
(for position see
8
4.
Press and hold the “Learn/Erase” button (see fig. 1) while powering on the
receiver.
(If Jumper J1 is in left position at power up and the “Learn/Erase” button is
not pressed the receiver will stop and indicate error 4. Restart the receiver
while pressing the “Learn/Erase” button.)
5.
Continue to press the button until all Outputs LEDs are lit (see
10
in fig. 1).
6.
Release the button. The Output LEDs will now display the current toggle
configuration. LED 7 (see
7
in fig. 1) will indicate relay configuration mode
with a slow blink (1 Hz).
7.
Use button 1...6 on the transmitter to configure the outputs as momentary or
remaining (latched). Output LED lit indicates remaining mode active.
8.
To store the configuration press the learn button for 1 second. Successful
store is indicated with 3 flashes on LED 7.
9.
Power off the receiver (if you have a conversion box for 230 V AC wait 10
seconds).
10.
Reinstall the Jumper in its previous setting.
11. Start the receiver.