Consider the placement recommendations when designing your facility’s
security system. Only professionals should carry out the design and installation
of the security system. A list of authorized o cial Ajax partners is
Design and preparation
It is important for the security system to work correctly to prepare the project
and install the detectors and devices properly. Failure to follow the basic
installation rules and recommendations of the user manual may result in
detector malfunction, false alarms, or loss of connection with already installed
devices.
When designing the layout scheme of the detectors, consider the wiring diagram
of the power cables laid on the site. Signal cables must be laid at a distance of
at least 50 cm from the power cables when lying parallel, and, if they intersect, it
must be at a 90° angle. Keep in mind that detectors are connected in sequence
if multiple devices are connected to the bus.
The maximum number of connectable devices for the Hub Hybrid is 100 at the default
settings.
How to calculate the number of connectable detectors (in progress)
For facilities that are under construction or renovation, cables are laid after the
wiring of the facility. Use protective tubes to route system cables to organize
and secure the wires. Ties, clips, and staples can be used to secure them.
When laying wires externally (without mounting them inside the walls), use a
box channel. Channels and boxes should be no more than half- lled with cables.
Do not allow cables and wires to sag. Where possible, hide the box channel from
direct view, for example, behind the furniture.