AJAX Fire Protect Скачать руководство пользователя страница 7

Setting

 

Value

 

First field 

Device name, can be edited 

Room 

Selecting the virtual room to which the device is assigned 

Dangerous CO Level Alarm 
(

FireProtect Plus only

If active, the detector alerts of exceeding the limits of carbon 
monoxide concentration 

High temperature alarm 

If active, the detector reacts when the temperature is 60°C and 
higher 

Rapid temperature rise alarm 

If active, the detector reacts to rapid temperature increase (30°С 
for 30 minutes or less) 

Alert with a siren if smoke is detected 

If active, Home Siren and Street Siren are activated in case of 
smoke alarm 

Alert with a siren if temperature 
threshold exceeded 

If active, Home Siren and Street Siren are activated in case if 
temperature threshold exceeded 

Alert with a siren if rapid temperature 
rise detected 

If active, Home Siren and Street Siren are activated in case if 
rapid temperature rise detected 

Alert with a siren if CO detected (

Fire 

Protect Plus only

When turned on, Home Siren and Street Siren are activated in 
case if CO concentration is dangerous 

Jeweller Signal Strength Test 

Switches the device to the signal strength test mode 

Fire Protect Self-Test 

Starts Fire Protect self-test 

User Guide 

Opens the detector User Guide 

Un pair Device 

Disconnects the sensor from the hub and deletes its settings 

Indication 

Event

 

Indication

 

Detector switching on 

The logo lights up green for 1 second 

Detector switching off 

The logo blinks red three times and the device switches off 

Registration failed 

The logo blinks green for a minute, then the device switches to 
the autonomous mode 

Smoke or temperature increase 
detected 

The siren switches on, the logo lights red during the fire/smoke 
alarm 

Battery low 

 

One short sound signal per 90 sec — main batteries low (CR2) 

Содержание Fire Protect

Страница 1: ...ect Fire Protect Plus communicates with the hub at a distance of up to 1 300 m in line of sight The detector can be a part of third party security systems connecting to them via the Ajax uartBridge or Ajax ocBridge Plus integration module The detector is set up via the Ajax apps for iOS Android macOS and Windows The system notifies the user of all events through push notifications SMS and calls if...

Страница 2: ...nfrared light between the emitter and photoelectric receiver This distortion triggers a smoke alarm When the temperature exceeds 60 С or rises by 30 С during 30 minutes not necessary to reach 60 С the detector registers temperature increase which triggers a fire alarm In case of alarm the detector activates the built in buzzer the siren sound can be heard from afar and blinks with the light indica...

Страница 3: ...ng the hub user guide install the Ajax app Create the account add the hub and create at least one room 2 Switch on the hub and check the internet connection via Ethernet cable and or GSM network 3 Make sure that the hub is disarmed and does not update by checking its status in the Ajax app Only users with administrator rights can add the device to the hub Pairing the detector with hub 1 Select Add...

Страница 4: ...work of the hub at a single protected object The connection request is transmitted for a short time at the moment of switching on the device If pairing with the hub fails the detector operates autonomously switch off the detector for 5 seconds and retry The detector connected to the hub is displayed in the list of devices in the app The update of the detector status in the list depends on the devi...

Страница 5: ...ength between the hub and the detector Connection Connection status between the hub and the device Battery Charge Primary battery level of the device Lid The tamper state of the device reacts to the detachment Routed Through ReX Displays the status of using the ReX range extender Smoke Shows if smoke is detected Temperature threshold exceeded The state of temperature threshold exceeded alarm ...

Страница 6: ...e of dangerous CO level alarm Backup Battery Charge Backup battery level of the device Smoke sensor The state of the smoke detector Smoke sensor dust level The dust level in the smoke chamber Firmware Detector firmware version Device ID Device identifier Setting 1 Devices 2 Fire Protect Fire Protect Plus 3 Settings ...

Страница 7: ...se detected If active Home Siren and Street Siren are activated in case if rapid temperature rise detected Alert with a siren if CO detected Fire Protect Plus only When turned on Home Siren and Street Siren are activated in case if CO concentration is dangerous Jeweller Signal Strength Test Switches the device to the signal strength test mode Fire Protect Self Test Starts Fire Protect self test Us...

Страница 8: ...e paragraph on Jeweller settings in hub settings According to the requirements of EN50131 standard the level of the radio signal sent by wireless devices is decreased during the test mode Detector Testing Before installing the detector check the smoke sensor To test it switch on the detector and press the sensor button the logo centre for a few seconds the detector will test the smoke chamber with...

Страница 9: ...detector even a 20 cm shift can significantly improve the quality of signal reception If the detector has low or unstable signal strength even after moving use a ReX Radio signal range extender Install the detector at the ceiling in the highest point where hot air and smoke are concentrated in case of fire If there are any beams at the ceiling protruding by 30 or more centimetres from the ceiling ...

Страница 10: ...takes it off the attachment panel the security system notifies you Do not install the detector 1 outside the premises outdoors 2 nearby any metal objects or mirrors causing attenuation or screening of the signal 3 at any places with fast air circulation air fans open windows or doors 4 closer than a meter to the cooking surface 5 inside premises with the temperature and humidity beyond the range o...

Страница 11: ...ol acetone gasoline and other active solvents to clean the detector To a certain level the detector ignores the dust in the smoke chamber When the chamber becomes too dusty the detector notifies the user of the need to clean it via the app and beeps every minute and a half Such maintenance is compulsory for the detector to operate correctly Pre installed batteries ensure up to 4 years of autonomou...

Страница 12: ...869 2 MHz depending on the region of sale Compatibility Operates independently or with Hub Hub Plus Hub 2 ReX ocBridge Plus uartBridge Maximum RF output power Up to 20 mW Radio signal modulation GFSK Radio signal range Up to 1 300 m any obstacles absent Power supply 2 CR2 main batteries CR2032 backup battery 3 V Battery life Up to 4 years Operating temperature range From 0 С to 65 С Operating humi...

Страница 13: ...nstallation kit 6 Quick Start Guide Warranty Warranty for the AJAX SYSTEMS MANUFACTURING LIMITED LIABILITY COMPANY products is valid for 2 years after the purchase and does not apply to the pre installed battery If the device does not work correctly you should first contact the support service in half of the cases technical issues can be solved remotely ...

Отзывы: