![AJAX Fire Protect Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/ajax/fire-protect/fire-protect_user-manual_2883481007.webp)
Setting
Value
First field
Device name, can be edited
Room
Selecting the virtual room to which the device is assigned
Dangerous CO Level Alarm
(
FireProtect Plus only
)
If active, the detector alerts of exceeding the limits of carbon
monoxide concentration
High temperature alarm
If active, the detector reacts when the temperature is 60°C and
higher
Rapid temperature rise alarm
If active, the detector reacts to rapid temperature increase (30°С
for 30 minutes or less)
Alert with a siren if smoke is detected
If active, Home Siren and Street Siren are activated in case of
smoke alarm
Alert with a siren if temperature
threshold exceeded
If active, Home Siren and Street Siren are activated in case if
temperature threshold exceeded
Alert with a siren if rapid temperature
rise detected
If active, Home Siren and Street Siren are activated in case if
rapid temperature rise detected
Alert with a siren if CO detected (
Fire
Protect Plus only
)
When turned on, Home Siren and Street Siren are activated in
case if CO concentration is dangerous
Jeweller Signal Strength Test
Switches the device to the signal strength test mode
Fire Protect Self-Test
Starts Fire Protect self-test
User Guide
Opens the detector User Guide
Un pair Device
Disconnects the sensor from the hub and deletes its settings
Indication
Event
Indication
Detector switching on
The logo lights up green for 1 second
Detector switching off
The logo blinks red three times and the device switches off
Registration failed
The logo blinks green for a minute, then the device switches to
the autonomous mode
Smoke or temperature increase
detected
The siren switches on, the logo lights red during the fire/smoke
alarm
Battery low
•
One short sound signal per 90 sec — main batteries low (CR2)