![AJAX Fire Protect Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/ajax/fire-protect/fire-protect_user-manual_2883481002.webp)
Functional Elements
1. Siren hole
2. Light indicator (acts as the sensor and Test button)
3. Smoke chamber hole with the temperature detector behind the net
4. Smart Bracket attachment panel
5. Power button
6. Tamper button
7. QR code
Operating Principle
When smoke penetrates the detector chamber, it distorts infrared light
between the emitter and photoelectric receiver. This distortion triggers a
smoke alarm. When the
temperature exceeds 60°С or rises by 30°С during
30 minutes (not necessary to reach 60°С), the detector registers
temperature increase, which triggers a fire alarm.
In case of alarm, the detector activates the built-in buzzer (the siren sound
can be heard from afar) and blinks with the light indicator. When connected
to a security system, both the user and the security company are notified of
the alarm.