NOTE FOR THE REPLACING OF MEMORY IC
If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken to
ensure correct data settings while making reference to TABLE 1.
NOTE: Initial Data setting will not be possible if clock has been set. To reset clock, either unplug AC cord and allow
at least 30 minutes before Power On or alternatively, discharge backup capacitor.
ADDRESS
DATA
00
80
01
6D
02
21
03
00
04
00
05
00
06
A4
07
EB
08
31
09
90
ADDRESS
DATA
0A
2B
0B
17
0C
C0
0D
FF
0E
FF
0F
FF
10
6C
11
2B
12
21
13
15
ADDRESS
DATA
14
0C
15
A0
16
63
17
44
18
A8
19
0F
1A
04
1B
CA
1C
5F
1D
F9
ADDRESS
DATA
1E
44
1F
05
20
88
21
06
22
25
23
00
24
39
25
01
26
00
27
3A
Table 1
1.
2.
3.
Fig. 1
ADDRESS is now selected and should "blink". Using the SET + or - keys on the remote, step through the ADDRESS until
required ADDRESS to be changed is reached.
Press ENTER to select DATA. When DATA is selected, it will "blink".
Again, step through the DATA using SET + or - until required DATA value has been selected.
Pressing ENTER will take you back to ADDRESS for further selection if necessary.
Repeat steps 4 to 7 until all data has been checked.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
4.
5.
6.
7.
8.
9.
The unit will now have the correct DATA for the new MEMORY IC.
Enter DATA SET mode by setting VOLUME to minimum.
While holding down VOLUME button on front cabinet, press key 6 on remote control simultaneously.
ADDRESS and DATA should appear as FIG 1.
INIT 00 83
0010
0003
POWER ON
PLAY/REC
ADDRESS
DATA
C4-1