-36-
ADJUSTMENT -1/1
XA-DV1
1. DC OFFSET Adjustment
Conditions:
• Measuring instrument : Oscilloscope (DC range)
Digital multi-meter
FUNCTION : DVD STOP state
Output side : Dummy resistance (8ohms) connection
Test point : SP OUT, J301 (FRONT Lch and Rch)
J401 (SURROUND Lch, Rch / CENTER / SUB WOFER)
Adjustment point : SFR301 (FRONT Lch)
SFR302 (FRONT Rch)
SFR401 (SURROUND Lch)
SFR402 (SURROUND Lch)
SFR451 (SUB-WOOFER )
SFR452 (CENTER)
1. As shown in the above figure, please connect SP OUT,J301(FRONT Lch) of a set.
2. Please adjust so that the display of digital multi-meter goes into 0
±
±
10mV. Moreover,
please check whether the center of the noise of an oscilloscope is a center.
3. Please adjust other channels similarly. (Only SUB-WOOFER : lessthan 0 20mV)
1
IC451
IC401
IC301
1
SFR451
SFR452
SFR401
SFR402
SFR301
SFR302
J401
J301
MAIN C.B PARTS SIDE
OSCILLOSCOPE
DIGITAL MULTIMETER
DUMMY
LOAD
SET
GND
CH1
SP OUT+
SP OUT–
V
8ohm