27
<MW/LW Adjustment>
Make sure that the following settings are done before adjustment.
Preparation
* Measuring instruments:
Standard Signal Generator (S.S.G.) / Loop antenna / Oscilloscope / Millivoltmeter / Dummy resistor (6
Ω
)
(1) Connect the measuring instruments as shown in the diagram below.
(2) Keep a distance of 60cm between the loop antenna of signal generator and the one connected to the unit.
DUMMY
SPOUT(L)
AC MILLIVOLTMETER
CH2
CH1
6
Ω
OUTPUT
OSCILLOSCOPE
CH2
CH1
LOAD
60cm
SET
Standerd Signal Genertaor
SPOUT(R)
5. IF Adjustment (MW)
Requirements
* Test point: SP OUT (Lch, Rch)
(1) Adjust the S.S.G. setting to AM; carrier at 999 kHz, distortion rate at 30 %, and source 1 kHz.
(2) Adjust the unit to MW 999 kHz.
(3) While monitoring the 1 kHz waveform through oscilloscope, decrease the S.S.G. output level (till slight noises appear in
the waveform).
(4) Adjust L802 so that the millivoltmeter indicates maximum.
6. Tracking Adjustment (MW)
Requirements: Same as Item 5.
(1) Adjust the S.S.G. setting to AM; carrier at 999 kHz, distortion rate at 30 %, and source 1 kHz.
(2) Adjust the unit to MW 999 kHz.
(3) While monitoring the 1 kHz waveform through oscilloscope, decrease the S.S.G. output level (till slight noises appear in the
waveform.
(4) Adjust L951 (1/3) so that the millivoltmeter indicates maximum.
7. Tracking Adjustment (LW)
Requirements: Same as Item 5.
(1) Adjust TC942 to the mechanical center.
(2) Adjust the S.S.G. setting to AM; carrier at 144 kHz, distortion rate at 30 %, and source 1 kHz.
(3) Adjust the unit to LW 144 kHz.
(4) While monitoring 1 kHz waveform through oscilloscope, decrease the S.S.G. output level (till slight noises appear in the
waveform).
(5) Adjust L941 so that the millivoltmeter indicates the maximum level.
(6) Adjust the S.S.G setting to AM; carrier at 290 kHz; distortion rate at 30 %, and source at 1 kHz.
(7) Adjust the unit to LW 290 kHz.
(8) While monitoring 1 kHz waveform through oscilloscope, decrease the S.S.G. output level (till slight noises appear in the
waveform).
(9) Adjust TC942 so that the millivoltmeter indicates the maximum level.
(10) Repeat the above steps 2 to 9 two to three times.
8. Auto-Stop Function Check (MW)
Requirements: Same as Item 5.
(1) Adjust the S.S.G setting to AM; carrier at 999 kHz; distortion rate at 30 %; source at 1 kHz, and output at 78 dBuv.
(2) Start the tuning search mode, and check that the auto-stop function is applied at MW 999 kHz.
Standard Signal Generator
Содержание NSX-R50
Страница 12: ... 12 SCHEMATIC DIAGRAM 1 MAIN 1 2 ...
Страница 13: ... 13 SCHEMATIC DIAGRAM 2 MAIN 2 2 TUNER ...
Страница 14: ... 14 SCHEMATIC DIAGRAM 3 HP ...
Страница 16: ... 16 SCHEMATIC DIAGRAM 4 FRONT LED DECK ...
Страница 17: ... 17 WIRING 3 PT 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 A B C D E F G H I J K L M N O P Q R S T U ...
Страница 18: ... 18 SCHEMATIC DIAGRAM 5 PT ...
Страница 20: ... 20 IC BLOCK DIAGRAM ...
Страница 21: ... 21 ...
Страница 22: ... 22 FL BJ854GNK BNF 1 GRID ASSIGNMENT ANODE CONNECTION GRID ASSIGNMENT ANODE CONNECTION ...
Страница 39: ...2 11 IKENOHATA 1 CHOME TAITO KU TOKYO 110 JAPAN TEL 03 3827 3111 Printed in Singapore 9301978 9720501 921338 ...