![Aiwa ADC-EX108 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/aiwa/adc-ex108/adc-ex108_service-manual_2880846004.webp)
- 4 -
1. How to Use the Repair Jig
Use the following repair jig kit for servicing.
The kit contains the following parts (Refer to Fig-1) ;
1.
FFC (26P/25 cm)
1 pcs
2.
P.W.B. FLEX
1 pcs
3.
P.W.B. JIG
1 pcs
4.
TRANSISTOR (2SD-2395)
1 pcs
5.
P.W.B. KEY
1 pcs
(1)
Remove the cabinet as follows;
1)
Remove the CABI BOTTOM by removing the
four screws VTT+2.6-6B (Refer to Fig-2).
(2)
Remove the P.W.B. MAIN as follows;
1)
Remove all terminals of the transistor Q623
(2SD2395) by unsoldering them.
2)
Remove the two motor wires (BLU/WHT).
3)
Remove the two wires (BLK/BRN) of the sensor
(PD201).
4)
Remove the P.W.B. MAIN from the unit by
removing the four screws V+2-3.
5)
Disconnect the FFC of pickup from CN101.
6)
Disconnect the PWB FLEX from CON1.
7)
Remove the LED (LED201,GL380) from the
P.W.B. MAIN.
8)
Remove the sensor (PS201,SENR GP1S94) from
P.W.B. MAIN.
(3)
Install the repair jig as follows;
1)
Install the P.W.B. JIG into the unit and fix it with
screws. (Refer to Fig-3).
Attach the parts as follows, (Refer to Fig-4);
Attach the supplied transistor to the location of the
P.W.B. MAIN from which Q623 is removed in
step (2).
2)
Connect the supplied PWB FLEX to CON1.
• When the CONTROL UNIT is not used, use the
P.W.B. KEY instead. (Refer to step (6), How to
use the repair jig.)
3)
Connect the FFC cable to CON101 and pickup.
(The supplied FFC cannot be used because pitches
and number of pins are different.)
SERVICE JIG AND TOOLS
Part name
Part code
For 10 CD changer
JIG-ADC-EX106
SV-J00-090-010
Fig-1
Fig-2
Fig-3
Fig-4
FFC
FFC
TRANSISTOR
PWB KEY
REMOVE SCREW
LED(LED201)
REMOVE MOTOR WIRE
PWB FLEX
REMOVE SENSOR WIRE
Q623
PICKUP FCC
SENSOR (PS201)
PWB JIG
Q623
PWB FLEX
FFC CABLE
PWB JIG