7

Subject to change without notice  |  83030000bUK |  ait-deutschland GmbH

WPSK 40Split

WTPSK 101Split

• yes    – no

• | – | –

• | • | –

B

B

W

28

41

l

39

120

l

39

120

bar

6

6

bar

9

9

°C

5 I 95

5 | 95

°C

7 | 35

7 | 35

%

65

65

kW

• yes    – no

• | –

• | –

mm

42

• yes    – no

• | –

• | –

813644

813643

Relative humidity maximum (non-condensing)

General unit data

Maximum output of electric heating element

Room temperature minimum | maximum

Tank name

Series buffer tank | Stratified storage tank | Stratified storage tank solar

Heating water reservoir

Energy efficiency class according to ErP
Standing loss according to ErP (at 65°C)
Total tank volume according to ErP
Nominal capacity
Max. operating pressure
Test pressure
Operating temperature minimum | maximum

Installation location

Insulation

Material: Rigid foam | soft foam

Sheet metal jacket ı Foil jacket

Manufacturer: ait deutschland GmbH | Index: a

Insulation thickness

WPSK 40Split – WTPSK 101Split

Technical Data

Содержание 813643

Страница 1: ...UK 83030000bUK Accessories for heat pumps Operating Manual Buffer Tanks Split ...

Страница 2: ...his operating manual is intended only for persons assigned to work on or operate the unit Treat all constituent parts confidentially The information contained herein is protected by copyright No part of this manual may be reproduced transmitted copied stored in electronic data systems or translated into another language either wholly or in part without the express written permission of the manufac...

Страница 3: ...isposal 5 9 Scope of delivery 5 9 1 Accessories 5 10 Transport Installation Assembly 5 10 1 Transport to installation location 5 10 2 Installation 6 10 3 Installation of the sensor s 6 11 Insulation of the connections and the storage tank 6 12 Draining the storage tank 6 Technical Data 7 WPSK 40Split WTPSK 101Split 7 Dimensional drawings 8 WPSK 40Split 8 WTPSK 101Split 9 Installation plans 10 WPSK...

Страница 4: ...understand the activities and the resulting consequences and can car ry out the necessary activities Children and adults who are not experienced in hand ling the product and do not understand the necessa ry activities and the resulting consequences must be instructed and if necessary supervised by persons experienced in handling the product and who are re sponsible for safety Children must not pla...

Страница 5: ...mbly Observe the following when performing all work IMPORTANT The tank must be installed in a frostproof room to prevent frost damage to the storage tank pipe system and connections NOTE Install the storage tank as close as possible to the heat generator to keep the heat losses as low as possible Ensure the shortest pos sible pipe lengths to the load IMPORTANT The floor or ground at the place of i...

Страница 6: ...cope of delivery for the heating and heat pump regulator in the sensor pocket s provided Position Dimensional drawings from page 8 for the respective model 2 Connect the sensor s to the regulator according to the terminal diagram Terminal diagram for the respective model in the heat pump operating manual 11 Insulation of the connections and the storage tank NOTE Insulate in accordance with applica...

Страница 7: ...ure minimum maximum Tank name Series buffer tank Stratified storage tank Stratified storage tank solar Heating water reservoir Energy efficiency class according to ErP Standing loss according to ErP at 65 C Total tank volume according to ErP Nominal capacity Max operating pressure Test pressure Operating temperature minimum maximum Installation location Insulation Material Rigid foam soft foam She...

Страница 8: ...hnischen Änderungen vorbehalten Alle Maße in mm A Vorderansicht C Draufsicht A C 495 330 445 4 3 2 1 Keys UK81513 All dimensions in mm Pos Name Dimension A Front view C Plan view 1 Return from heating R 1 2 Return to heat pump R 1 Net weight 16 kg Nominal volume 39 litres Dimensional drawings WPSK 40Split ...

Страница 9: ... 1 3 Fühler Ø i 10mm 4 Rücklauf Heizkreis Wärmepumpe G 1 5 Blindstopfen 6 Vorlauf Wärmepumpe G 1 Nettogewicht 41 kg Nenninhalt 120 Liter 4 3 2 1 A B C D E F 4 3 2 1 Schutzvermerk ISO 16016 beachten Keys UK819533 All dimensions in mm Pos Name Pos Name A Front view C Plan view B Side view from left G Detail view Pos Name Dimension 1 Bleeding G 1 2 2 Flow heating circuit G 1 3 Sensor Ø i 10 mm 4 Retu...

Страница 10: ... 490 FS 819515 Änderungen vorbehalten mm nsicht m für Servicezwecke A 5 4 3 2 www D I ait 4 3 2 Zust Änderungstext Datum Von Erstell Gepr Norm to Al DIN IS DM 09 06 20 PEP 013 2019 a Keys UK819515 All dimensions in mm Pos Name A Front view FS Free space for servicing Installation plan WPSK 40Split ...

Страница 11: ...920 FS A egende DE819535 Technische Änderungen vorbehalten Alle Maße in mm A Vorderansicht FS Freiraum für Servicezwecke 5 4 3 2 1 4 3 2 1 Zust Änderungstext Datum 27 01 22 p675 Keys UK819535 All dimensions in mm Pos Name A Front view FS Free space for servicing WTPSK 101Split Installation plan ...