19
EN
•
Activation delay.
This allows you to select a delay time for switching on the production unit,
configurable in minutes, from 0 to 7 (by default, 3 min.).
•
DHW function.
(Only available in installations with AZX6GAW[XXX] gateway)
This allows
you to activate or deactivate (On/Off) the domestic hot water (DHW) function in the systems
connected to the CCP. Function activated by default.
•
Cooling mixing valve.
(Only available in installations with AZX6GAW[XXX] gateway)
This
allows you to configure the operation of your installation depending on whether or not you
have a cooling mixing valve.
Select Manual in the case of having cooling mixing valves in your installation, in which case
they must be set at 18 °C. If the installation does not have a cooling mixing valve, select Auto
so that the installation works automatically with the temperature read by the system. By
default, it is set to Manual.
•
LWT temperatures.
(
Only available in installations with AZX6GAW[XXX]
gateway, provided
that the air to water unit is not configured to work automatically, allowing the imposition
of working temperatures) This allows you to define the LWT temperatures of the air to
water unit for cooling and heating modes. The temperature range is defined by the AC unit.
Default values:
- Air in cooling mode: 10 ºC
- Radiant in cooling mode: 18 °C
- Air in heating mode: 50 °C
- Radiant in heating mode: 35 °C
Mode
Demand
Control relays
O1
O2
O3
O4
O5
O6
Stop
Off
-
-
-
-
-
-
Cooling
Air
ON
-
ON
-
-
-
Radiant
ON
-
-
ON
-
-
Off
ON
-
-
-
-
-
Heating
Air
-
ON
-
-
ON
-
Radiant
-
ON
-
-
-
ON
Off
-
ON
-
-
-
-
Dry
On
ON
-
-
-
-
-
Off
ON
-
-
-
-
-
Ventilation
On
-
-
-
-
-
-
Off
-
-
-
-
-
-
1.
2.
2 pipes / 4 pipes*
*Note:
In this configuration, the indoor unit will remain in Standby mode once comfort has
been reached in all zones.