FRAMING

A

B

INNER COACH WALL

OUTER COACH WALL

FLOORING

A=325 MM + 3MM - 0

B=325 MM + 3MM - 0

Figure 1

A

FRAMED OPENING

DETAIL A

SPECIAL SCREW

CONTROL HOUSING

GASKET

DOOR LATCH

RADIUS CORNER DOOR FRAME

CONTROL HOUSING

HINGE ROD

RADIUS CORNER DOOR

SILICONE CAULKING INNER EDGE OF

CONTROL HOUSING

CAULK AROUND OPENING

TO SEAL CONTROL HOUSING

TO SKIN, WATER TIGHT

FRAMED OPENING

(SEE FIGURE NO. 1)

EXTERIOR

COACH SKIN

CAULK ALL THE WAY AROUND DOOR FRAME TO

SEAL FRAME TO COACH WALL, WATER TIGHT

(SEE DETAIL A)

MOUNTING SCREWS, FRAME TO COACH WALL

(11) REQ'D.

MOUNTING SCREW (SPECIAL)

DOOR FRAME TO CONTROL HOUSING

(3) REQ'D.

SILICONE CAULKING

DOOR FRAME

MOUNTING SCREW

AC JUNCTION BOX

Figure 2

SECURE CHOCKS, ONE ON EACH SIDE, TIGHTLY AGAINST WATER HEATER JACKET

AND FASTEN TO VEHICLE FLOOR TO PREVENT MOVEMENT. CHOCKS SHOULD BE

APPROXIMATELY 2" X 2" X 6"  

FRAMED OPENING

COMPARTMENT

BOTTOM

Figure 3

HOT

COLD

Figure 4

3

B.

  The following is information regarding Hot Water Services and corrosion of the 

tank in Australia. The single biggest factor is metal/water contact.

 1.

  Mains Water Connection- For correct performance and warranty of the 

unit, when connected to mains water supply, pressure must be limited 

to approximately 350 KPA (50 PSI) by the use of a suitable pressure 

regulator. Failure to do so will void warranty.

 2.

  A  Suitable  1/2”  BSPT  fitting  must  be  used  for  coupling  HWS  to  water 

supply.

 3.

  Water supply is an overall factor.

 4.

  Tanks should be drained and flushed regularly - how often depends on 

soluble/silt content in water. Outback areas will be more of a problem than 

major city supplies.

 5.

  Do not use bore water. This will void your warranty as the salt contents of 

bore water are extremely high.

 6.

  The life of the anodes, which are a low valve replacement part, varies with 

water quality. Anodes must be inspected periodically. Use only genuine 

Suburban anode rods. Use of other anodes may void the warranty. Please 

see Anode Protection Section.

 7.

  Your water system should be operated periodically even though the van is 

not being used, at least twice per week.

 8.

 Anodes must be checked every 6 (six) months. Please see Anode 

Protection Section.

SAFETY WARNINGS

WARNING!  It is imperative that the water heater tank be filled with water 

before operating the water heater.  Operation of the water heater without 

water in the tank may result in damage to the tank and/or controls.  This 

type of damage is not covered by the limited warranty.

WARNING!  Hydrogen  gas  may  result  if  you  have  not  used  this  heater 

for two weeks or more. HYDROGEN GAS IS EXTREMELY FLAMMABLE. 

To reduce the risk of injury under these conditions, open the hot water 

faucet for several minutes at the kitchen sink before you use any electrical 

appliance connected to the hot water system. If hydrogen is present, you 

probably will hear an unusual sound such as air escaping through the 

pipe as the water begins to flow.

Hydrogen gas may be present even after water has been drained from the 

tank. Open faucet at sink and allow system to vent for several minutes 

(5-10 minutes).

Do not smoke or have any open flame near the open faucet.

Should overheating occur, shut off the electrical supply.

Do not use this appliance if any part has been submerged under water. 

Immediately call an authorised service technician to inspect the appliance 

and to replace any part of the control system that has been submerged 

under water.

Do not alter the operation of your water heater nor change the design/

construction of your water heater. Accessories are being marketed for 

RV products which we do not recommend. For your safety, only factory 

authorized parts are to be used on your water heater

Pressure  relief  valve  to  be  operated  at  least  once  every  6  months  to 

remove lime deposits and verify it is not blocked. Failure to do so may 

result in heater exploding. Continuous leakage from valve may indicate 

a problem with unit.

NOTE:  Always  open  both  the  cold  and  hot  water  faucets  when  filling 

vehicle  water  tank  to  allow  air  pockets  to  be  forced  out  of  the  water 

heater.  When water flows from the heater faucets, close both faucets.

WARNING! Do not store or use combustible materials or liquids near 

or  adjacent  to  this  heater.  The  appliance  shall  not  be  installed  in  any 

location where flammable liquids or vapors are likely to be present.

Be  sure  the  power  is  “OFF”  to  the  water  heater  during  any  type  of 

refueling and while vehicle is in motion or being towed.

WARNING! The thermostat on your water heater is not adjustable. It is 

a temperature sensing limit designed to maintain a temperature of 60°C 

to comply with AS/NZS 3500 Part 4.2. Water temperatures over 60°C can 

cause severe burns instantly or death from scalds; therefore, be careful 

when using hot water. Children, disabled and elderly are at highest risk of 

being scalded. Always feel water before bathing or showering. Children 

or infirm persons must not adjust or operate any electrical controls on 

this unit.

Содержание SW5EA

Страница 1: ...OR ANY OTHER APPLIANCE THIS APPLIANCE SHALL NOT BE INSTALLED IN ANY OTHER LOCATION WHERE FLAMMABLE LIQUIDS OR VAPORS ARE LIKELY TO BE PRESENT WARNING THIS APPLIANCE IS UNSUITABLE FOR USE AS A POOL HEA...

Страница 2: ...seal frame to coach skin G Fit the door frame into control housing over the caulking already applied and pull frame tight to control housing using the three 3 No 8 15 x 3 1 2 screws provided H Push wa...

Страница 3: ...trols This type of damage is not covered by the limited warranty WARNING Hydrogen gas may result if you have not used this heater for two weeks or more HYDROGEN GAS IS EXTREMELY FLAMMABLE To reduce th...

Страница 4: ...Valve when your water heater is operating Water weeping or dripping from the P T Valve does not always mean the P T Valve is defective As water is heated it expands The water system in a recreational...

Страница 5: ...not equipped with a bypass kit and you intend to winterize by adding antifreeze to the system remove the anode rod storing it for the winter and replace it with a 19mm drain plug FOR YOUR SAFETY READ...

Страница 6: ...g repair parts from your dealer or a distributor always give the following information 1 Part Number Not Item No 2 Part Description 3 Model No and Serial No of your Heater 4 Number of Parts Required I...

Страница 7: ...MODEL SERIAL NO PLATE 1 3 5 9 20 2 14 21 8 22 11 10 17 15 19 18 16 12 23 25 Figure 8 7 INCORRECT INCORRECT CORRECT Figure 9 Figure 10 Figure 11...

Страница 8: ...y or diagnosis without repair 3 Damage or repairs required as a consequence of faulty or incorrect installation or application not in conformance with installation instructions 4 Failure to start or o...

Отзывы: