Airxcel SW5EA Скачать руководство пользователя страница 2

SPECIFICATIONS AND DATA FOR SUBURBAN STORAGE HOT WATER HEATER

 

         

 

1.

 

Specifications:

 

  

Capacity:

 

 

 

 

 

17.7 Liters (SW5EA) 

26.4  Liters (SW7EA) 

  

Maximum Working Pressure:

 

  850 

kPa  

  

Electrical:

   

Heating Element

 

 

 

240 Volts 50 HZ A.C. 1440 Watts 6 Amp     

 

2. Width:

 

     320mm 

  

  

Height:

 

     320mm 

  

  

Depth:

       

 

 

 

 

450mm  (SW5EA) 

500mm (SW7EA) 

 

3.

 

Location of hot water inlet is 70mm from top dead center.

 

 

Location of cold water inlet is 55mm from bottom dead center.

 

4.

 

DO NOT

 place articles on or against this appliance.

  

DO NOT

 use or store flammable materials near this appliance.

INSTALLATION REQUIREMENTS

WARNING! Installation of this appliance must be made in accordance with 

the written instructions provided in this manual. No agent, representative 

or employee of Suburban or other person has the authority to change, 

modify  or  waive  any  provision  of  the  instructions  contained  in  this 

manual.

NOTE:    Do  not  install  the  water  heater  with  the  door  facing  toward  the 

forward end of the coach.  See Figures 9, 10 and 11.

This appliance shall be installed only by authorised persons and in accordance 

with the manufacturer’s installation instructions, electrical wiring regulations, local 

water supply regulations, and any other statutory regulations. Installation shall be 

in accordance with AS/NZS 3500.4.

1.

  Discharge pipe must be mounted at the pressure relief valve and installed 

through floor line of caravan or motor home, and must be left open to free 

air so as water can escape if required and is to be installed in a continuously 

downward direction and in a frost-free environment. For convenience, a break 

-thru grommet has been provided in the bottom of the control housing. The 

center of the grommet may be pierced and piping routed through.

2.  

A mains pressure reducing valve must be installed in the incoming water 

line with a rating of 350 kPa (50 psi). 

Please Note:

 Warranty will be void if 

pressure reducing valve is not installed.

INSTALLATION INSTRUCTIONS

Keep the heater at least 25mm clear of anything that is combustible, like walls, 

cupboards and timber.

Provide an opening flush with floor in outer wall of coach as shown. Wall of coach 

should be framed as shown in Figure 1. Maintain inside dimensions listed below. 

Do not install on carpet unless the carpet is covered by a metal shield at least 

50mm greater than the width of the water heater.

INSTALLATION USING HINGED DOOR

(See Figure 2 for illustration)

A. 

In some limited accessibility applications, the chocks as illustrated in Figure 3 

must be installed prior to setting water heater into position.  Install chocks, one 

on each side of water heater, as illustrated in Figure 3.

B. 

Position heater into framed opening as illustrated.

C. 

On mesa or yoder type sidewalls, flatten the wall area around the opening.

D. 

Caulk around framed opening (trailer skin) as illustrated.

E. 

Lay a bead of silicone caulking (or suitable caulking) around the inner edge of 

the control housing (top, bottom and sides). See detail “A” in illustration. This 

will seal frame to control housing.

F.

  Apply a bead of silicone caulking (or suitable caulking) around back side of 

door frame. See detail “A” in illustration. This will seal frame to coach skin.

G.

  Fit the door frame into control housing (over the caulking already applied) and 

pull frame tight to control housing using the three (3) No. 8-15 x 3 1/2” screws 

provided.

H. 

Push water heater into framed opening until back side of door frame (now 

attached to control housing) is against the side of the coach and firmly attach 

with screws around the perimeter of the frame. 

NOTE

: The two (2) holes in 

bottom of frame identified as “A” in Figure 2 are also used to mount door hinge 

to the frame.

I.

  If already installed, confirm chocks are supporting the water heater correctly.  

If not already completed, install chocks, one on each side of water heater as 

illustrated in Figure 3.

J. 

Attach door to frame as illustrated.

K. 

Close the door so that the door latch protrudes through the slot in the door. 

Turn latch 90 degrees to fasten door.

2

MAKING WATER CONNECTIONS

WARNING! A tempering valve or other similar device must be installed 

between the outlet of the hot water service and any faucet.

Connect water lines to rear of unit. Suitable fittings must be used in rear of hot 

and cold water connections. 

DO NOT

 glue metal fittings. This will void warranty.

NOTE

: Inside each fitting is a plastic fill tube installed by manufacturer. Its purpose 

is to enhance water circulation. 

DO NOT REMOVE THE PLASTIC FILL TUBES.

Fill tank with water. Always open both the cold and hot water taps when filling 

vehicle water tank to allow air pockets to be forced out of the water heater. When 

tank is filled, turn off taps and check for leaks at connections.

After leak testing, drain water from tank.

MAKING ELECTRICAL CONNECTIONS

240 VOLTS A.C.

A. 

Refer to Figure 2 for location of A.C. junction box.

B. 

The electrical connection must be made to conform with the local authority 

having jurisdiction or in the absence of such requirement with the latest 

Australian electrical code. All electrical work to be conducted by a licensed 

electrician.

C. 

Check rating plate and wiring diagram (Figure 5) before proceeding. Install 

a fused safety switch or circuit breaker of adequate capacity between heater 

and electrical power source. Attach the active and neutral wires from the fused 

switch or breaker to corresponding terminals in heater junction box. An earth 

wire from a well grounded source must be attached to the earth terminal in the 

junction box.

CAUTION: Before applying the 240 VAC power to the water heater junction 

box, be sure the switch for electric element is in the “OFF” position.

WARNING! Before the switch for the electric

 

element is turned to the 

“ON”  position,  the  water  heater  tank  must  be  filled  with  water.    See 

“SAFETY WARNINGS”

MAINTENANCE

WARNING! If the user of this appliance fails to maintain it in the condition 

in which it was shipped from the factory or if the appliance is not used 

solely for its intended purpose or if appliance is not maintained in 

accordance with the instructions in this manual, then the risk of a fire 

exists which can cause personal injury, property damage or loss of life.

WARNING: For your safety, all repairs should be performed by an 

authorised service person.

A.

  Periodically check wiring and wire connection to be sure wiring is not damaged/

frayed and that all terminals and connections are tight and in compliance with 

codes (See “Making Wire Connections”).

Содержание SW5EA

Страница 1: ...OR ANY OTHER APPLIANCE THIS APPLIANCE SHALL NOT BE INSTALLED IN ANY OTHER LOCATION WHERE FLAMMABLE LIQUIDS OR VAPORS ARE LIKELY TO BE PRESENT WARNING THIS APPLIANCE IS UNSUITABLE FOR USE AS A POOL HEA...

Страница 2: ...seal frame to coach skin G Fit the door frame into control housing over the caulking already applied and pull frame tight to control housing using the three 3 No 8 15 x 3 1 2 screws provided H Push wa...

Страница 3: ...trols This type of damage is not covered by the limited warranty WARNING Hydrogen gas may result if you have not used this heater for two weeks or more HYDROGEN GAS IS EXTREMELY FLAMMABLE To reduce th...

Страница 4: ...Valve when your water heater is operating Water weeping or dripping from the P T Valve does not always mean the P T Valve is defective As water is heated it expands The water system in a recreational...

Страница 5: ...not equipped with a bypass kit and you intend to winterize by adding antifreeze to the system remove the anode rod storing it for the winter and replace it with a 19mm drain plug FOR YOUR SAFETY READ...

Страница 6: ...g repair parts from your dealer or a distributor always give the following information 1 Part Number Not Item No 2 Part Description 3 Model No and Serial No of your Heater 4 Number of Parts Required I...

Страница 7: ...MODEL SERIAL NO PLATE 1 3 5 9 20 2 14 21 8 22 11 10 17 15 19 18 16 12 23 25 Figure 8 7 INCORRECT INCORRECT CORRECT Figure 9 Figure 10 Figure 11...

Страница 8: ...y or diagnosis without repair 3 Damage or repairs required as a consequence of faulty or incorrect installation or application not in conformance with installation instructions 4 Failure to start or o...

Отзывы: