PARTS ILLUSTRATION AND REPLACEMENT PARTS LIST

PARTS LIST FOR MODELS:  SW4DA • SW6DA  • SW4DEA • SW6DEA

 

Only factory authorized parts are to be used. 

Do not attempt to repair defective parts.

When ordering repair parts from your dealer or a distributor, always give the following information:     

 

1. 

Part Number (Not Item No.)

 

2. 

Part Description

 

3. 

Model No. and Serial No. of your Heater

 

4.

 Number of Parts Required

ITEM 

NO.

DESCRIPTION

PART 

NUMBER

1

Module Board

521114 

3

Cover, Module Board

090613

6

Bushing, Snap 1/2”

070270

7

Bushing, Strain Relief 5/8”

230216

8

D.C. Junction Box Assembly

090517

10

Flue Collector Assembly Complete

102434

12

Valve, Pressure Relief (SW4DEA, SW6DEA)

161166 

Valve, Pressure Relief (SW4DA, SW6DA)

13

Screw #10 x 1/4

121577

15

Cover, Thermostat/Hi-Limit

090562

16

Gasket, Thermostat Cover

070987

18

Grommet

070874

20

Bracket, Electrode Mounting

063187

21

Electrode

232258

26

Burner Assembly with orifice

010844

27

Air Shutter Assembly (Main Burner)

010857

28

Electric Element with Gasket
(Only for SW4DEA, SW6DEA)

520831

29

Anode

232767

31

Grommet

071246

32

Bushing, Snap 1/2” (Only for SW4DEA. SW6DEA)

070270

33

Switch, Electric Element (Only for SW4DEA, SW6DEA)

233110

33A

Gasket, Switch (Only for SW4DEA, SW6DEA)

071016

34

Gas Fitting

170374

35

Bracket, Valve Mounting

063243

36

Valve, Gas (LP)

161164

ITEM 

NO.

DESCRIPTION

PART 

NUMBER

37

Manifold, Outlet

171420

38

Screw #10 x 1/4 (4 Required)

121577

39

Screw #8-32 x 3/8 Type F (2 Required)

121934

41

Switch Assembly, 12 V.D.C. T-Stat/Hi-Limit (All Models)

232319

42

Switch Assembly, 220 V.A.C. T-Stat/Hi Limit
(Only for SW4DEA, SW6DEA)

232317

44

Cover, Junction Box (Only for SW4DEA, SW6DEA)

090576

45

Grommet, Gas Inlet

070989

46

Bushing, Snap 7/8” (Only for SW4DEA, SW6DEA)

230218

47

A.C. Junction Box Assembly
(Only for SW4DEA, SW6DEA)

090575

48

Nut, 10-24 Keps (Green)

121576

49

Bushing, Snap 7/8” (Only for SW4DEA, SW6DEA)

230218

50

Foam Jacket (SW6DEA, SW6DA)

520868

Foam Jacket SW4DEA, SW4DA)

520867

51

Switch, Lamp and Plate Assembly 

232589

52

Screw 8mm - 4.0 x 1/2 Hex Washer Head (2 Required)

121943

53

Burner Bracket 

063444

55

1/4 Loxit Nut (Manifold to Burner)

171463

56

1/4 Loxit Nut (Manifold to Valve)

171463

57

Electrode Wire (Not Shown)

232456

58

Gasket, Element Cover (Only for SW4DEA, SW6DEA)

070988

59

Cover, Element (Only for SW4DEA, SW6DEA)

090445

61

Door, Radius Corner “PW” (Not Shown)

Arctic White

Black

Polar White

6270AAW

6270AEB

6270APW

62

Terminal Block (Only for SW4DEA, SW6DEA)

232669

63

Plug, Break through

233309

9

Содержание SW4DEA

Страница 1: ...OR GAS SUPPLIER ADDITIONAL SAFETY DO NOT STORE OR USE PETROL OR OTHER COMBUSTIBLE MATERIALS OR LIQUIDS NEAR OR ADJACENT TO THIS HEATER OR ANY OTHER APPLIANCE THIS APPLIANCE SHALL NOT BE INSTALLED IN...

Страница 2: ...ning D Caulk around framed opening trailer skin as illustrated E Lay a bead of silicone caulking or suitable caulking around the inner edge of the control housing top bottom and sides See detail A in...

Страница 3: ...nty Please see Anode Protection Section 7 Your water system should be operated periodically even though the van is not being used at least twice per week 8 Anodes must be checked every 6 six months Pl...

Страница 4: ...Sulphur water can be caused by a chemical action or by bacteria The solution to eliminate is chlorination of the water system Add about 17 75 cL of chlorinated common household liquid bleach to each 3...

Страница 5: ...sing The water temperature will be regulated by the thermostat This procedure is necessary so as to prevent 240 V element and gas heating from operating simultaneously TO TURN OFF WATER HEATER 1 Turn...

Страница 6: ...BL R R Y BK 1 2 3 4 IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE WATER HEATER MUST BE REPLACED IT MUST BE REPLACED WITH 18 GA 105 C WIRE OR IT S EQUIVALENT SWITCH HI LIMIT T STAT MODULE BD SPARK C...

Страница 7: ...ld have with the heater IF AFTER CHECKING THE CHART AND THE UNIT WILL STILL NOT PERFORM TURN THE APPLIANCE OFF AND CONTACT THE AUTHORISED SERVICE PROVIDER SOOTING WILL NOT COME ON NOT ENOUGH HOT WATER...

Страница 8: ...36 31 45 41 29 50 51 1 3 52 15 8 48 7 6 27 42 58 28 59 33 32 47 44 49 48 46 33A 62 13 10 63 Figure 9 SW4DEA AND SW6DEA MODEL SERIAL NO PLATE 12 16 18 20 21 53 26 39 35 38 34 37 55 56 36 45 41 29 50 5...

Страница 9: ...Electric Element Only for SW4DEA SW6DEA 233110 33A Gasket Switch Only for SW4DEA SW6DEA 071016 34 Gas Fitting 170374 35 Bracket Valve Mounting 063243 36 Valve Gas LP 161164 ITEM NO DESCRIPTION PART N...

Страница 10: ...CORRECT INCORRECT INCORRECT Figure 10 Figure 11 Figure 12 10...

Страница 11: ...11...

Страница 12: ...y or diagnosis without repair 3 Damage or repairs required as a consequence of faulty or incorrect installation or application not in conformance with installation instructions 4 Failure to start or o...

Отзывы: