Airxcel SW4DEA Скачать руководство пользователя страница 5

8.

  If  lockout  occurs  before  main  burner  lights,  turn  switch  to  “OFF”,  wait  five 

seconds and turn switch to “ON” position. This will restart the ignition cycle. 

The first start-up of the heater may require several ignition cycles before all air 

is purged from the gas lines.

If the burner will not come on, the following items should be checked before calling 

a service person.

1. 

Switch turned off.

2.

 Gas supply to heater is empty or turned off.

3. 

Reset button on ECO is tripped

OPERATING INSTRUCTIONS

 FOR UNITS WITH ELECTRIC ELEMENT

Electric water heaters are designed to operate with a minimum amount of service 

problems; however, proper operation and care is essential.

By far the most common trouble with electric water heaters results from energizing 

the water heater before it is filled with water. Even brief operation of the electric 

element without water in the tank will burn-out the electric heating element.

Turn off gas supply to the water heater. To energize the electric heating element, 

turn the switch to “ON.” Reverse the procedure to disconnect electric heating 

element.
The switch is located behind the water heater door in the lower left corner of the 

control housing. The water temperature will be regulated by the thermostat.
This procedure is necessary so as to prevent 240 V element and gas heating from 

operating simultaneously.

TO TURN OFF WATER HEATER

1. 

Turn switch to “OFF” position.

2. 

Turn off electrical power to the appliance.

3. 

Turn off gas supply.

4.

  If  vehicle  is  to  be  stored  or  heater  is  going  to  be  turned  off  while  subject 

to  freezing  temperature,  drain  water  heater.  (See  “Draining  and  Storage 

Instructions.”) 

Figure 2

(Models SW4DEA and SW6DEA)

A

FRAMED OPENING

DETAIL A

SPECIAL SCREW

CONTROL HOUSING

GASKET

DOOR LATCH

RADIUS CORNER DOOR FRAME

CONTROL HOUSING

HINGE ROD

RADIUS CORNER DOOR

SILICONE CAULKING INNER EDGE OF

CONTROL HOUSING

CAULK AROUND OPENING

TO SEAL CONTROL HOUSING

TO SKIN, WATER TIGHT

FRAMED OPENING

(SEE FIGURE NO. 1)

EXTERIOR

COACH SKIN

CAULK ALL THE WAY AROUND DOOR FRAME TO

SEAL FRAME TO COACH WALL, WATER TIGHT

(SEE DETAIL A)

MOUNTING SCREWS, FRAME TO COACH WALL

(11) REQ'D.

MOUNTING SCREW (SPECIAL)

DOOR FRAME TO CONTROL HOUSING

(3) REQ'D.

SILICONE CAULKING

DOOR FRAME

MOUNTING SCREW

AC JUNCTION BOX

DC JUNCTION BOX

FRAMING

A

B

INNER COACH WALL

OUTER COACH WALL

FLOORING

A=325 MM + 3MM - 0

B=325 MM + 3MM - 0

Figure 1

SECURE CHOCKS, ONE ON EACH SIDE, TIGHTLY AGAINST WATER HEATER JACKET

AND FASTEN TO VEHICLE FLOOR TO PREVENT MOVEMENT. CHOCKS SHOULD BE

APPROXIMATELY 2" X 2" X 6"  

FRAMED OPENING

COMPARTMENT

BOTTOM

Figure 1A

5

Содержание SW4DEA

Страница 1: ...OR GAS SUPPLIER ADDITIONAL SAFETY DO NOT STORE OR USE PETROL OR OTHER COMBUSTIBLE MATERIALS OR LIQUIDS NEAR OR ADJACENT TO THIS HEATER OR ANY OTHER APPLIANCE THIS APPLIANCE SHALL NOT BE INSTALLED IN...

Страница 2: ...ning D Caulk around framed opening trailer skin as illustrated E Lay a bead of silicone caulking or suitable caulking around the inner edge of the control housing top bottom and sides See detail A in...

Страница 3: ...nty Please see Anode Protection Section 7 Your water system should be operated periodically even though the van is not being used at least twice per week 8 Anodes must be checked every 6 six months Pl...

Страница 4: ...Sulphur water can be caused by a chemical action or by bacteria The solution to eliminate is chlorination of the water system Add about 17 75 cL of chlorinated common household liquid bleach to each 3...

Страница 5: ...sing The water temperature will be regulated by the thermostat This procedure is necessary so as to prevent 240 V element and gas heating from operating simultaneously TO TURN OFF WATER HEATER 1 Turn...

Страница 6: ...BL R R Y BK 1 2 3 4 IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE WATER HEATER MUST BE REPLACED IT MUST BE REPLACED WITH 18 GA 105 C WIRE OR IT S EQUIVALENT SWITCH HI LIMIT T STAT MODULE BD SPARK C...

Страница 7: ...ld have with the heater IF AFTER CHECKING THE CHART AND THE UNIT WILL STILL NOT PERFORM TURN THE APPLIANCE OFF AND CONTACT THE AUTHORISED SERVICE PROVIDER SOOTING WILL NOT COME ON NOT ENOUGH HOT WATER...

Страница 8: ...36 31 45 41 29 50 51 1 3 52 15 8 48 7 6 27 42 58 28 59 33 32 47 44 49 48 46 33A 62 13 10 63 Figure 9 SW4DEA AND SW6DEA MODEL SERIAL NO PLATE 12 16 18 20 21 53 26 39 35 38 34 37 55 56 36 45 41 29 50 5...

Страница 9: ...Electric Element Only for SW4DEA SW6DEA 233110 33A Gasket Switch Only for SW4DEA SW6DEA 071016 34 Gas Fitting 170374 35 Bracket Valve Mounting 063243 36 Valve Gas LP 161164 ITEM NO DESCRIPTION PART N...

Страница 10: ...CORRECT INCORRECT INCORRECT Figure 10 Figure 11 Figure 12 10...

Страница 11: ...11...

Страница 12: ...y or diagnosis without repair 3 Damage or repairs required as a consequence of faulty or incorrect installation or application not in conformance with installation instructions 4 Failure to start or o...

Отзывы: