background image

 

OPERATIONS GUIDE 

 

Make sure the selector switch is in the “OFF” position. 
 
1. 

Turn on the 240 volt power supply to the vehicle. 

 
2. 

To check fan operation:  Turn selector switch to 

 

“LOW FAN”, then to “HIGH FAN”.  Fan should 

 

run continuously at low speed on “LOW FAN” and 

 

continuously at high speed on “HIGH FAN”.  See 

 

Figure 1. 

 
3. 

To check cooling operation, turn the selector switch 

 

to “LOW COOL” and then to “HIGH COOL”.  

 

Compressor and fan should run at both positions.   

 

Fan should run on low speed on “LOW COOL” and 

 

on high speed on “HIGH COOL”.  See Figure 1. 

 

NOTE 

 

 

For compressor operation, the room temperature  

 

must be above the lowest thermostat setting  

 

(approximately 58 degrees F).  If the temperature is 

 

below this setting, the compressor will not start. 

 

Also, in the cooling mode the thermostat controls 

 

only the compressor operation. 

 

4.

 

To check a model with Elect-A-Heat, turn the 

 

selector switch to “HEAT” and the thermostat to 

 

“WARMER”.  Check the heat output. 

 

NOTE 

 

 

For heating, the thermostat is factory adjusted to 

 

cycle “OFF” when the return air temperature is 

 

between 80 and 85 degrees F.  If the electric heat 

 

does not come on, it is likely that the coach 

 

temperature is over 80 degrees F. 

 
 

To actuate the heater for operation checkout under 

 

this condition, run the air conditioner for five to ten 

 

minutes (to “cold-soak” the air distribution chamber), 

 

then follow through with the heater checkout. 

 

MAINTENANCE 

 

A. 

Electrical 

 

 

All electrical work and/or inspection should be 

 

performed only by qualified service personnel. 

 

Contact your nearest Airxcel, Inc. service center 

 

if electrical problems should arise. 

 

B. 

Check Points 

 

 

Failure to start or to cool the air are sometimes 

 

problems with air conditioning units.  The 

 

Coleman-Mach air conditioner is designed to 

 

operate on 240 volt electrical power. 

 
 

If the compressor on the air conditioner fails to 

 

start, check with your Airxcel, Inc. service center 

 

to determine that the proper wire size is connected 

 

to the unit, the proper circuit breakers are installed 

 

as protection devices on the electrical circuit and 

 

the proper sized extension cord is being used for  

 

the distance covered from the utility outlet to the 

 

RV.  The required minimum wire size is #14 AWG 

 

for lengths up to 25 feet (larger wire size for greater 

 

distances).  Each air conditioning unit must be 

 

protected with a time delay fuse or circuit breaker: 

 
 

Series 6000 – 15 Amp 

 

Series 7000 – 15 Amp 

 

Series 8000 – 15 Amp 

 

If the air conditioner continues to trip off the circuit 

 

breaker, have an electrician check the starting 

 

amperage and running amperage on the unit.  If the 

 

circuit breaker continues to trip off and the electrical 

 

consumption is found to be normal, it will require the 

 

replacement of the faulty circuit breaker. 

 
 

If all electrical power to the air conditioner is normal 

 

but neither the fan or the compressor will operate, the 

 

connector plug located behind the ceiling assembly 

 

control box should be checked to determine whether 

 

it is faulty. 

 
 

If all electrical power to the unit is normal and the fan 

 

runs but you never get any heated air, then the 

 

electrical plug to the heating unit should be checked 

 

for a secure connection.  If this does not correct the 

 

malfunction, the heating thermostat or limit switch 

 

may be faulty. 

 

C. 

Mechanical Integrity 

 
 

The air conditioner should be inspected periodically 

 

to be sure that the bolts which secure the unit to the 

 

roof are tight and in good shape.  Also, an 

 

examination of the plastic shroud covering the air 

 

conditioner on the roof of the roof should be made 

 

periodically.  Be sure the four screws are snug and 

 

holding the shroud to the air conditioner.  While 

 

examining the tightness of these screws, also 

 
 

Содержание 6000 series

Страница 1: ...NDITIONERS MODES D EMPLOIS ET UTILISATION DES CLIMATISEURS DE LA SERIE 6000 7000 ET 8000 ENTRETIEN UND INSTANDHALTUNG ANSWEISUNGEN FUR KLIMAANLAGEN SERIE 6000 7000 UND 8000 INSTRUCCIONES PARA LA OPERACIÓN Y EL MANTENIMIENTO DES LOS DISPOSITIVOS DE AIRE ACONDICIONADO DES LAS SERIES 6000 7000 Y 8000 ...

Страница 2: ... designed to operate on 240 volt electrical power If the compressor on the air conditioner fails to start check with your Airxcel Inc service center to determine that the proper wire size is connected to the unit the proper circuit breakers are installed as protection devices on the electrical circuit and the proper sized extension cord is being used for the distance covered from the utility outle...

Страница 3: ...sur LOW FAN VENTILATEUR FAIBLE puis sur HIGH FAN VENTILATEUR FORT Le ventilateur doit fonctionner sans interruption a regime faible sur LOW FAN et a regime fort sur HIGH FAN Voir Figure 1 3 Pour verifier la fonction de refroidissement mettre le selecteur de mode sur LOW COOL REFROIDISSEMENT FAIBLE puis sur HIGH COOL REFROIDISSEMENT FORT Le compresseur et le ventilateur doivent marcher sur les deux...

Страница 4: ...rage et de marche Si le declenchement du disjoncteur se poursuit alors que la consommation electrique reste normale il sera necessaire de remplacer le disjoncteur defectueux Si alors que l alimentation electrique du climatiseur est normale ni le ventilateur ni le compresseur ne fonctionnent verifier la connexion de la prise situee a l arriere de la boite de commande du module Si l alimentation en ...

Страница 5: ...n nur von Wartungsfachleuten durchgefuhrt werden Bei elektrischen Storungen mit der nachsten Airxcel Inc Wartungszentrale Verbindung aufnehmen B Fehlersuche Es kann vorkommen daß die Klimaanlage nicht anlauft oder die Luftkuhlung nicht funktioniert Die Coleman Mach Klimaanlage ist fur einen Betrieb mit einer Netzspannung von 240V ausgelegt Wenn der Kompressor Ihrer Klimaanlage nicht anspringt erku...

Страница 6: ...nuamente a alta velocidad en HIGH FAN Vea la Figura 1 vea la página 3 3 Para comprobar que la unidad enfría ponga el interruptor seleccionador en LOW COOL poco frío y después en HIGH COOL mucho frío El compresor y el ventilador deben funcionar en ambas posiciones El ventilador debe funcionar a baja velocidad en LOW COOL y a alta velocidad en HIGH COOL Vea la Figura 1 vea la página 3 NOTA Para que ...

Страница 7: ...mal estado Si toda la alimentación de electricidad al dispositivo de aire acondicionado es normal pero ni el ventilador ni el compresor funcionan se debe inspeccionar el enchufe del conector situado detrás de la caja de controles del montaje para techo a fin de determinar si está en mal estado Si toda la alimentación de electricidad a la unidad es normal y el ventilador funciona pero el aire no se...

Страница 8: ...8 RV Products Division Airxcel Inc RV Products Division P O Box 4020 Wichita KS 67204 1976F184 Rev 1 1 10 PP ...

Отзывы: