5-12
PERFORMANCE DATA & PRESSURE CURVES
Service Manual - DUO Series
5.5.2
Heating Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR DB ID COIL ( °C)
15
20
25
ENTERING AIR
WB OU COIL ( °C)
TH
PI
TH
PI
TH
PI
-10
3.10 1.43 2.98 1.53 2.86 1.60
-7
3.34 1.47 3.22 1.55 3.10 1.63
-2
3.54 1.49 3.43 1.58 3.31 1.66
2
4.31 1.56 4.13 1.66 3.96 1.75
6
5.53 1.67
5.37 1.79
5.18 1.90
10
6.01 1.77 5.85 1.89 5.69 2.02
15
6.50 1.84 6.34 1.99 6.18 2.11
20
6.85 1.90 6.69 2.06 6.50 2.22
*
the above chart includes the weighted deicing infleuence.
LEGEND
TH –
Total Heating Capacity, kW
PI
– Power Input, kW
WB –
Wet Bulb Temp., (
o
C)
DB –
Dry Bulb Temp., (
o
C)
ID
–
Indoor
OU –
Outdoor