5-2
PERFORMANCE DATA & PRESSURE CURVES
Service Manual - DUO Series
5.1.2
Heating Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR DB ID COIL ( °C)
15
20
25
ENTERING AIR
WB OU COIL ( °C)
TH
PI
TH
PI
TH
PI
-10
3.12 1.49 3.00 1.58 2.88 1.66
-7
3.36 1.53 3.24 1.61 3.12 1.70
-2
3.56 1.54 3.45 1.64 3.33 1.73
2
4.34 1.62 4.16 1.72 3.98 1.82
6
5.56 1.74
5.40 1.86
5.21 1.98
10
6.05 1.84 5.89 1.96 5.72 2.10
15
6.53 1.92 6.37 2.06 6.21 2.19
20
6.89 1.97 6.72 2.14 6.53 2.31
*
the above chart includes the weighted deicing infleuence.
LEGEND
TH –
Total Heating Capacity, kW
PI
– Power Input, kW
WB –
Wet Bulb Temp., (
o
C)
DB –
Dry Bulb Temp., (
o
C)
ID
–
Indoor
OU –
Outdoor