CONTROL SYSTEM
Service Manual-CN Fixed RPM series
12-27
C. Deicing procedure
OCT [
o
c]
ON
OFF
ON
OFF
ON
L
ANY
COMP
OFAN
RV
IFAN
DST
(DDT)
0
WSHP 15
Others 12
OFF
HEs are forced ON
DOC
ANY
ON
HE
36s
36s
DT
30s
max 12 min.
Note 3
DI (note 1)
DI (note 2)
30s
3 min
3 min
IFAN
OFF
ANY
HE
OFF
ANY
al
l S
H
unit
s
excep
t WAX
RC or
WAX u
n
it
s
HEs are forced OFF
IFAN is forced to Low Speed
BLINK
ON
OPER
LED
Notes :
1. In the following Deicing cycles, the time interval between two Deicing
cycles activation is between 30 to 80 min.
2. For RC group, HEs are forced OFF. IFAN operation is as in Heat Mode,
Sect 4.0.3.a, i.e. IFAN will be set to OFF when ICT<30
o
c.
Содержание ONG3-17 R410A
Страница 1: ...CN Fixed RPM Series REFRIGERANT R410A HEATPUMP REV 01 Oct 2008...
Страница 21: ...Pressure Curves Service Manual CN Fixed RPM series 6 2 6 1 2 Heating...
Страница 22: ...Pressure Curves Service Manual CN Fixed RPM series 6 3 6 2 Model CN12 GCN 12 R410A 6 2 1 Cooling...
Страница 23: ...Pressure Curves Service Manual CN Fixed RPM series 6 4 6 2 2 Heating...
Страница 24: ...Pressure Curves Service Manual CN Fixed RPM series 6 5 6 3 Model CN18 ONG3 17 R410A 6 3 1 Cooling...
Страница 25: ...Pressure Curves Service Manual CN Fixed RPM series 6 6 6 3 2 Heating...
Страница 27: ...Sound Level Characteristices Service Manual CN Fixed RPM series 7 2...
Страница 29: ...Sound Level Characteristices Service Manual CN Fixed RPM series 7 4...
Страница 31: ...Wiring Diagrams Service Manual CN Fixed RPM series 9 1 9 WIRING DIAGRAMS 9 1 Indoor Unit CN 9 12 18...
Страница 32: ...Wiring Diagrams Service Manual CN Fixed RPM series 9 2 9 2 Outdoor Unit GCN 9 R410A GCN 12 R410A ONG3 17 R410A...
Страница 33: ...Wiring Diagrams Service Manual CN Fixed RPM series 9 3 9 3 Connections between indoor unit and outdoor unit...
Страница 86: ...EXPLODED VIEWS AND SPARE PARTS LISTS Service Manual CN Fixed RPM series 14 2 17...
Страница 87: ...EXPLODED VIEWS AND SPARE PARTS LISTS Service Manual CN Fixed RPM series 14 3 14 2 EXPLODED VIEWS GCN 9 12...
Страница 88: ...EXPLODED VIEWS AND SPARE PARTS LISTS Service Manual CN Fixed RPM series 14 4 14 3 EXPLODED VIEWS ONG3 17...
Страница 94: ...APPENDIX A Service Manual CN Fixed RPM series 15 1 APPENDIX A INSTALLATION AND OPERATION MANUAL...
Страница 95: ...English Installation manual Indoor unit cassette type Part Number 468050324 01 AIR CONDITIONER CASSETTE...
Страница 119: ...PROTECTION 468100326...
Страница 121: ......
Страница 122: ...3...
Страница 124: ......
Страница 125: ......
Страница 127: ......