CONTROL SYSTEM
Revision 0
11-33
11.15.2 By Remote Control Settings:
a. STEP 1: TURNING ON THE POWER.
Turn ON the power, make sure that the unit is in operation.
b. STEP 2 : ENABLE SELF-TEST MODE
1) Use the remote control to send the first settings to display / indoor unit HEAT
mode, HIGH IFAN, set temperature to 16 ºC
,
no I-FEEL Sleep or any other
timer settings are needed.
2) Cover the IR transmitter components in the remote control so that it will not
transmit the signals to the indoor unit display.
3) Use the remote control to send the second settings to display / indoor unit
COOL mode, LOW IFAN, no I-FEEL Sleep or any other timer settings.
4) Uncover the remote control IR transmitter and change the temperature
settings. If the display/indoor unit receive the settings properly the following
steps will start:
c. STEP 3: MODEL SETTING CONFIRMATION
1) The STAND-BY and COOL LEDS will indicate the operation mode as follows:
COOL LED
STAND-BY LED
OPERATION MODE
OFF
ON
ST
OFF
OFF
RC
ON
OFF
SH
ON
ON
RH
2) Testing the Model configuration. Selected by the COMP, STAND-BY, TIMER
LEDS and FILTER will indicate the model configuration as follows (the
relevant line for this manual is highlighted):
FILTER LED
TIMER LED
OPERATE LED
COMP
MODEL
OFF
OFF
OFF
ON
WNG
ON
OFF
OFF
ON
MBX
OFF
ON
OFF
ON
WNX
OFF
OFF
ON
ON
PRX
ON
OFF
ON
ON
WMN1
OFF
ON
ON
ON
EMD/LS
ON
ON
ON
ON
ECC-K
OFF
ON
OFF
OFF
WMN 4
ON
ON
OFF
OFF
PXD
ON
OFF
ON
OFF
WMN
2/WHX
ON
ON
ON
OFF
WMN 3
In this term the step motor will turn to HOME POSITION.
Содержание K XLN24 RC 3PH
Страница 12: ...OUTLINE DIMENSIONS Revision 0 4 1 4 OUTLINE DIMENSIONS 4 1 K XLN 24 30...
Страница 13: ...OUTLINE DIMENSIONS 4 2 Revision 0 4 2 Outdoor Unit OU724 4 3 Outdoor Unit OU830...
Страница 29: ...WIRING DIAGRAMS Revision 0 7 3 7 5 Outdoor Unit OU724 OU830 3PH...
Страница 31: ...ELECTRICAL CONNECTIONS 8 2 Revision 0 8 3 K XLN 24 30 3PH...
Страница 32: ...REFRIGERATION DIAGRAMS Revision 0 9 1 9 REFRIGERATION DIAGRAMS 9 1 Heat Pump Models 9 1 1 K XLN 24 R410A...
Страница 33: ...REFRIGERATION DIAGRAMS 9 2 Revision 0 9 1 2 K XLN 30 R410A...
Страница 34: ...REFRIGERATION DIAGRAMS Revision 0 9 3 9 2 Cooling Only Models 9 2 1 K XLN 24 30...
Страница 37: ...CONTROL SYSTEM 11 2 Revision 0 11 1 3 Main PCB Controller...
Страница 75: ...EXPLODED VIEWS AND SPARE PARTS LIST 13 2 Revision 0 17 18 19 20 25 26 21 22 23 24 27 28 32 29 31 33 34 30 35...
Страница 78: ...EXPLODED VIEWS AND SPARE PARTS LIST Revision 0 13 5 13 3 Exploded view of outdoor unit ONG...
Страница 79: ...EXPLODED VIEWS AND SPARE PARTS LIST 13 6 Revision 0...