TROUBLESHOOTING
Version - 1 48 DCH DCI
10.2.10 Inverter compressor drive error diagnosis and solution (P4)
Error Code
P4
Malfunction decision
conditions
An abnormal inverter compressor drive is detected by a special
detection circuit, including communication signal detection,
voltage detection, compressor rotation speed signal detection
and so on.
Supposed causes
●
Wiring mistake
●
IPM malfunction
●
Outdoor fan ass’y faulty
●
Compressor malfunction
●
Outdoor PCB faulty
Trouble shooting:
Check the wiring between main PCB
and compressor
Correct the connection or replace
the wires and connectors.
Yes
No
Check the IPM
No
Yes
Replace the IPM board or replace
the main PCB
Check the outdoor fan and the
outdoor unit ventilation
No
Please refer to the solution of
【
Fan
Speed Has Been Out Of Control
】
malfunction
Yes
Check the compressor resistance
values
No
Replace the compressor.
Yes
Replace the outdoor main PCB
Содержание JSP023054
Страница 12: ...DIMENSION Version 1 12 DCH DCI For JOSI DCH009 N11 For JOSI DCH012 N11 For JOSI DCH018 N11 ...
Страница 13: ...DIMENSION DCH DCI 13 Version 1 For JOSI DCH024 N11 ...
Страница 18: ...WIRING DIAGRAM Version 1 18 DCH DCI 6 2 Model JOAU DCY009 H11 JOAU DCY012 H11 ...
Страница 57: ...EXPLODED VIEW AND SPARE PART LIST DCH DCI 57 Version 1 11 5 Exploded view of model JOSI DCH024 N11 ...
Страница 62: ...EXPLODED VIEW AND SPARE PART LIST Version 1 62 DCH DCI 11 10 Exploded view of model JOAU DCY018 H11 ...
Страница 64: ...EXPLODED VIEW AND SPARE PART LIST Version 1 64 DCH DCI 11 12 Exploded view of model JOAU DCY024 H11 ...
Страница 66: ...SERVICE MANUAL DCH DCI Series ...