6.AIR FILTER LOCATION
The air filter is located in the rear side of the unit (default from factory) but can be easily relocated in the bottom of the unit if it is required.
7.AIR FILTER CLEANING
For cleaning the filter remove it by pushing up toward the back of the unit and pull it out as described below.
8.AIR FILTER RELOCATION
Remove air filter from the unit.
1
.
Remove panel4.
2
.
Remove filter trails 2-3.
3
.
Insert filter trails 2-3 on the opposite side of the unit. 5.Close panel 4 in the
4
.
rear side of the unit.
Insert the filter into the trails.
5
.
3
DISPLAY CONTROL UNIT
1.LOCATION CRITERIA
It is recommended to install the Display Control Unit close to a ceiling in a central and neutral zone at typical conditions. In addition, the aesthetic aspect
●
should be considered.
The Display Control Unit is connected to the main control board on the air conditioner (the indoor unit) by a communication cable. Cable is connected to the
●
Display Control Unit by a quick-connector. (8 pin plug)
2.INSTALLATION OF DISPLAY CONTROL UNIT ON WALL
Drill a 12 mm diameter hole on the wall, for routing the communication cable.
●
Open the unit cover, drill 3 holes in the wall to match the holes in the Display Control Unit, install the inserts and fasten the unit to the wall with 3 screws.
●
The Display Control Unit is provided of a special communication cable, 7 meters long, terminated by a plug, connected in the housing itself to a distribution
●
box, which enables the control of the air conditioner from several different rooms, each one from its own Display Control Unit.
Connect the quick connector to the appropriate socket on the main control board in the indoor unit electrical box.
●
3.CONSIDERATIONS IN LOCATING THE REMOTE CONTROL UNIT
a) Locate the Remote Control Unit in such a way that when mounted on its support on the wall, it will be in line sight with the Display Control
Unit (at less than 8 m).
b) It is recommended to establish the final location of the Remote Control Unit only after the first operation, assuring proper transmission and
reception between the Remote Control Unit and the Display Control Unit.
1.Main Control Board on Indoor Unit.
2.Distribution Board.
3.Communication Cable.
COLOR CHART
Conn. Point
Wire Color
Conn. Point
Wire Color
1
Blue
5
Purple
2
Green
6
Yellow
3
Black
7
Orange
4
Brown
8
Red