background image

Required tools for installation 

Attached accessories

No.

Accessories part

Qty.

No.

Accessories part

Qty. No.

Accessories part

Qty.

1

Installation paper board

 

                 

1

5

Pipe insulation                 

4

9

Clamp                               

6

2

Drain hose                   

1

6

Washer                        

4

10

Sealing material          

2

3

Insulation                              

 

1

7

Bolt                             

2

11

Operation

manual

Installation

manual    

                

2

4

Hoseclamp                         

1

8

Bolt                             

8

1.Screw driver 

4.Hexagonal wrench 

7. Knife 

2.Electric drill, hole core drill ( 60 mm) 

5.Pipe cutter 

8.Measuring tape 

3.Spanner 

6.Reamer 

9.Torque wrench 

Optional accessories

Name

Used for

Panel 625mmX625mm

Gird ceiling installation

Panel 725mmX725mm

Hard ceiling installation

Note

Decoration panel is separated from unit when packaging,

select proper panel for different installation situation.

1

SELECT THE BEST LOCATION

Do

 install the cassette in a place meets following conditions:

  1.  Allow max. Air flow to the desired space;

  2.  Allow max. Return airflow;

  3.  Ensure adequate drainage of condensed water;

  4.  Leave a minimum 250mm free space in front of the filter;

  5.  Allow a free service access to electrical box;

  6.  Allow easy access to the base of the indoor unit while providing enough space from the ceiling;

  7.  It is better to install the unit in the center of the room,and the installation height should over 2.3m.

  8.  The distance between air-conditioner and obstacles should meets the requirments in fig1.

Do not

 install the cassette in a place like following:

  1.  Do not install the cassette in a room where gasses, acids or inflammable products are stored, In order to avoid damage to the aluminum and copper 

evaporators and the internal plastic parts.

  2.  Do not install the cassette in a workshop or a kitchen. Oil vapor attracted by the treated air could form deposits on the cassette evaporators and 

modify their performance or damage the cassette's internal plastic parts.

  3.  Do not install the cassette in launary or a room where steam is produced.

  This air conditioner has the optional 2-way/3-way air discharging according to installation location. Use sealing material in accessory parts to seal the

   related air outlets.

Fig 1 Installation requirment

Fig 2 Air flow direction (example)

4-way direction (Default)

3-way direction

2-way direction

Отзывы: