11-15
CONTROL SYSTEM
SM BS DCI 1- A.1 GB
Model Depended Parameters:
Parameter name
Wall Mounted Models
DCI 9
DCI 12
DCI 18
DCI 21
NLOAD limits as a function of selected indoor fan speed
MaxNLOADIF1C 40
40
40
40
MaxNLOADIF2C 53
53
53
53
MaxNLOADIF3C 120
120
120
120
MaxNLOADIF4C 127
127
127
127
MaxNLOADIF5C 127
127
127
127
Indoor Fan speeds
IFVLOWC 700
700
700
800
700
800 800
900
1000
IFMEDC 900
950
1050
1100
IFHIGHC 1050
1100
1200
1250
IFTURBOC 1150
1200
1250
1300
IFVLOWH 700
700
700
800
IFLOWH 800
850
900
950
IFMEDH 950
1000
1100
1150
IFHIGHH 1100
1150
1200
1250
IFTURBOH 1200
1250
1300
1300
Nominal Compressor Frequency
NomLoadC 40
62
62
85
NomLoadH
55
67
74
80
Parameter Name
Floor mounted / Ducted
9 12
BS
12
18
NLOAD limits as a function of selected indoor fan speed
MaxNLOADIF1C 40
40
40
40
MaxNLOADIF2C 53
53
53
53
MaxNLOADIF3C
120 120
120 120
MaxNLOADIF4C 127
127
127
127
MaxNLOADIF5C 127
127
127
127
Nominal Compressor Frequency
NomLoadC 42
63
56
69
NomLoadH
61 71 76 77
CONTENTS