39
11.14 26
O
C lock funciton
Factory default the 26°C lock function is unavailable.
Setting method by remote controller:
(apply to all indoor units except AWSI-CCV060-N11)
Power on the unit, in cooling mode, low speed, setting the temperature 26°C. Press the “HEALTH” button of the
remote controller 8 times in 5s, buzzer echoes 4 times, the 26°C lock function is available; repeat above operations,
buzzer echoes 2 times, the 26°C lock function is unavailable.
Setting method for AWSI-CCV060-N11 by remote controller:
Power on the unit, press the "LIGHT" button 12 times, buzzer echoes 4 times, the unit panel will display "A", then
press the "LIGHT" button again, the unit panel will display "A0", press the temp. adjusting key, until the panel
display "Ab", press the "LIGHT" button to confirm, then the panel will display "00" or "01" (00: 26
O
C lock function is
unavailable; 01:26
O
C lock function is available), press the temp. adjusting key to select the "00" or "01" , then press
the "LIGHT" button to confirm. After 60s, the unit will exit the setting mode automatically.