HMF R22 Series 10 Version - 1
4. Refrigerant Cycle Diagram
For cooling only models:
INDOOR
OUTDOOR
LIQUID SIDE
GAS SIDE
HEAT
EXCHANGE
(EVAPORATOR)
HEAT
EXCHANGE
(CONDENSER)
COMPRESSOR
CAPILIARY TUBE
T2 Evaporator
temp. sensor
T1 Room temp.
sensor
ACCUMULATOR
For heat pump models:
LIQUID SIDE
GAS SIDE
HEAT
EXCHANGE
(EVAPORATOR)
HEAT
EXCHANGE
(CONDENSER)
COMPRESSOR
2-WAY VALVE
3-WAY VALVE
4-WAY VALVE
COOLING
HEATING
T2 Evaporator
temp. sensor
T1 Room temp.
sensor
T3 Condenser
temp. sensor
ACCUMULATOR
INDOOR
OUTDOOR
CHECK VALVE
(Heating Model only)
CAPILIARY TUBE
T3 temp. sensor is only for AWSI-HMF024-H61