TROUBLESHOOTING
SM HHD 1-A.1 GB
13-3
Malfunction
2x7
Segments
IDU LEDs
Possible causes / Actions
Stop rise/HZ down due to
IDU defrosting protection
FH
1. Poor air-return in indoor unit
2. Fan speed is abnormal
3. Evaporator is dirty.
DC Over Voltage
PH
COOL Indicator OFF 3S and blink 11
times
1. AC power supply is higher than 265V
2. Outdoor PCB circuit malfunction
DC Under Voltage
PL
HEAT Indicator OFF 3Sand blink21
times
1. AC power supply voltage is less than
150VAC
2. Outdoor PCB circuit malfunction
DC Over Current
P5
COOL Indicator OFF 3Sand blink15
times
1. Abnormal power input voltage.
2. Compressor wiring mistake.
3. Liquid and gas valve are not open.
4. EEV damaged or not proper working
5. Poor heat exchange.
6. Over charged system.
Charging malfunction of
capacitor
PU
HEAT Indicator OFF 3Sand blink17
times
1. Reactor open
2. Charging relay or other components
damaged on PCB.
HST Failure
P7
HEAT Indicator OFF 3Sand blink18
times
1. Senor was broken or damaged
2. PCB temperature detection cuircuit
has problem
HST over heating
protection
P8
HEAT Indicator OFF 3Sand blink19
times
1. Insufficient attachment of IPM module
to Heatsink
2. Outdoor PCB problem.
Compressor overload
protection
H3
HEAT Indicator OFF 3Sand blink3
times
1. EEV connection problem or damaged
2. Refrigeratn leakage
3. OLP damaged
IPM protection
H5
HEAT Indicator OFF 3Sand blink5
times
1.Abnormal power input voltage.
2.Compressor wiring mistake.
3.Liquid and gas valve are not open.
4.EEV damaged or not proper working
5.Poor heat exchage.
6.Over charged system.
No feedback of indoor
motor
H6
OPER Indicator OFF 3S and blink 11
times
1. Bad contact of DC motor feedback
terminal.
2. Bad contact of DC motor control end.
3. Fan motor is blocked.
4. Motor malfunction.
5. Malfunction of main board rev
detecting circuit.
Desynchronizing of
compressor
H7
HEAT Indicator OFF 3Sand blink7
times
1. Abnormal power input voltage.
2. Compressor wiring mistake.
3. Liquid and gas valve are not open.
4. EEV damaged or not proper working
5. Poor heat exchage.
6. Over charged system.
PFC protection
HC
HEAT Indicator OFF 3Sand blink6
times
1. PFC module assembly problem.
2. Poor heat exchange of Heatsink
3. PFC reactor problem.
4. Abnormal power voltage
5. PFC circuit problem on PCB
Outdoor DC fan motor
malfunction
L3
OPER Indicator OFF 3S and blink 23
times
1.DC fan motor malfunction or blocked
2.Bad connection
Over Power Protection
L9
OPER Indicator OFF 3S and blink 20
times
To protect the electronical components
when detect high power
IDU/ODU Mismatch
LP
OPER Indicator OFF 3S and blink19
times
Indoor unit and outdoor unit doesn't
match
Start-up Failure
LC
HEAT Indicator OFF 3Sand blink11
times
1. Compressor wiring mistake
2. Over charged system
3. System not balanced before
compressor starting
4. Compressor problem
Содержание AWAU-YHD009-H11
Страница 14: ...OUTLINE DIMENSION 4 2 SM HHD 1 A 1 GB 4 2 Outdoor YHD009 YHD012 4 3 Outdoor YHD018...
Страница 15: ...OUTLINE DIMENSION SM HHD 1 A 1 GB 4 3 4 4 Outdoor YHD024...
Страница 16: ...PERFORMANCE DATA SM HHD 1 A 1 GB 5 1 5 PERFORMANCE DATA 5 1 Model HHD009 YHD009 HHD012 YHD012...
Страница 17: ...PERFORMANE DATA 5 2 SM HHD 1 A 1 GB 5 2 Model HHD018 YHD018 HHD018 YHD018...
Страница 18: ...PRESSURE CURVES SM HHD 1 A 1 GB 6 1 6 PRESSURE CURVES TBD...
Страница 19: ...SOUND LEVEL CHARACTERISTICS SM HHD 1 A 1 GB 7 1 7 SOUND LEVEL CHARACTERISTICS 7 1 Sound Pressure Level...
Страница 20: ...SOUND LEVEL CHARACTERISTICS 7 2 7 2 Soud Pressure Level Spectrum Measured as Figure 1 TBD...
Страница 22: ...WIRING DIAGRAMS SM HHD 1 A 1 GB 9 1 9 WIRING DIAGRAM 9 1 HHD009 HHD012 9 2 HHD018 HHD024...
Страница 23: ...WIRING DIAGRAM 9 2 SM HHD 1 A 1 GB 9 3 YHD009 YHD012 9 4 YHD018 YHD024...
Страница 49: ...EXPLODED VIEW SPARE PART LIST SM HHD 1 A 1 GB 15 3 15 3 Exploded view of indoor unit HHD012 EV AWSI HHD012 N11...
Страница 51: ...EXPLODED VIEW SPARE PART LIST SM HHD 1 A 1 GB 15 5 15 5 Exploded view of indoor unit HHD018 EV AWSI HHD018 N11...
Страница 53: ...EXPLODED VIEW SPARE PART LIST SM HHD 1 A 1 GB 15 7 15 7 Exploded view of indoor unit HHD024 EV AWSI HHD024 N11...
Страница 62: ...APPENDIX 16 SM HHD 1 A 1 GB APPENDIX...