POWER SUPPLY
380-41 SV 3N/50Hz
Âllr§hN
5.Electrical Installation
PE----+-,----
-
�-,
L1
L1
L2--r--
-
----1L2
L3
L3
N
N
Outdoor nuit
lndoor nuit
Applicable for (380-41 SV/S0Hz)):: three phase model
1. To avoid abnormal operation of the unit caused by electromagnetic interference, attention should be paid
to avoid the interference signal source when connecting cables.
2. The wiring diagram is for reference only, when wiring, physical abjects will prevail!
5.6 Unit wiring
Note: The cross-sectional area of the conductor selected by user must not be less than the specifications listed
in the table. If the the user's power cord is tao far away from the unit, make a corresponding increase in the
cross-sectional area of the line group to ensure the normal power supply.
Power suppiy line specifications
:o��;
��:�
Outdoor power supply line
lndoor power supply
lndoor /outdoor
(quantity , diameter)
line (quantity, diameter)
connection line
Power supply method
H05RN-F
H05W-F
(quantity, Diameter)
Single phase 18K model
3X14AWG
/
4X16AWG
outdoor Power Supply
Single phase 24K model
3X14AWG
/
4X16AWG
outdoor Power Supply
Single phase ?36K mode
3X12AWG
/
4X16AWG
outdoor Power Supply
3-phase ?36K mode
5X14AWG
/
4X16AWG
outdoor Power Supply