background image

   

   

 

   

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

     

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

     

 

 

   

   

   

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

   

 

 

     

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

   

 

 

 

 

 

 

 

   

 

 

 

 

 

   

 

 

 

 

 

 

 

   

     

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

6. Function and Control

6.1 Remote Controller Introduction of RC08A

13

Содержание 7SP023102

Страница 1: ...y before installing or operating your new air conditioning unit Make sure to save this manual for future reference Service Manual HDL High Wall AW HDL018 N91 AW YHDL018 H91 7SP023102 7SP062962 R32 Eng...

Страница 2: ...Introduction of RC08A 13 3 Outline Dimension Diagram 6 3 1 Indoor Unit 6 3 2 Outdoor Unit 7 5 Electrical Part 9 5 1 Wiring Diagram 9 5 2 PCB Printed Diagram 11 Part Installation and Maintenance 26 7...

Страница 3: ...and Parts List 59 10 1 Indoor Unit 59 10 2 Outdoor Unit 61 11 Removal Procedure 63 11 1 Removal Procedure of Indoor Unit 65 11 2 Removal Procedure of Outdoor Unit 65 Appendix 69 Appendix 1 Reference S...

Страница 4: ...1 Service Manual Technical Information 1 Summary Part Technical Information Indoor Unit A1 Outdoor Unit Remote controller RC08A Caution Risk of fire flammable material...

Страница 5: ...Product Code Fan Type Cross flow Fan Diameter Length DXL mm 106X706 Cooling Speed SH H M L SL r min 1230 1130 1030 800 Heating Speed SH H M L SL r min 1350 1200 1050 900 Fan Motor Power Output W Fan...

Страница 6: ...air flow Super High Pipe length 5m Outdoor temp C Condition Indoor DB27 C WB19 C Indoor air flow High Pipe length 5m Condition Indoor DB27 C WB19 C Indoor air flow High Pipe length 5m Condition Indoo...

Страница 7: ...olution rps Indoor Outdoor P MPa T1 C T2 C 27 19 35 24 09K 0 8 1 1 12 to 15 65 to 38 Super High High 49 12K 11 to 14 64 to 37 60 18K 0 9 1 1 12 to 14 75 to 37 Super High High 52 24K 72 Instruction T1...

Страница 8: ...blowing Outdoor side noise when blowing Indoor fan motor rotating speed Compressor frequency Hz Noise dB A 50 60 30 40 20 Low Middle High Super High 50 52 54 56 58 60 62 64 68 20 0 3 0 4 50 60 70 80 9...

Страница 9: ...3 Outline Dimension Diagram 3 1 Indoor Unit Unit mm Unit mm Model W H D 18 970 300 225 W D H 24K 104 685 181 140 190 38 55 55 38 6...

Страница 10: ...3 2 Outdoor Unit 320 AW YHDL018 H91 7...

Страница 11: ...ction Heat exchanger evaporator Heat exchanger condenser Valve Valve Liquid pipe side Gas pipe side Strainer Strainer Capillary Accumlator Compressor 4 Refrigerant System Diagram Connection pipe speci...

Страница 12: ...Symbol Color Symbol Name WH White GN Green CAP Jumper cap YE Yellow BN Brown COMP Compressor RD Red BU Blue Grounding wire YEGN Yellow Green BK Black VT Violet OG Orange Note Jumper cap is used to det...

Страница 13: ...DFKLQH LV UXQQLQJ VWRSSLQJ RU KDV EHHQ SRZHUHG RII IRU OHVV WKDQ PLQXWHV WR SUHYHQW WKH ULVN 51 1 1 8 1 1 1 8 1 0 1 7 5 1 7 50 1 7 2 1 208 3 1 7 03 6 1625 7 03 6 1625 7 03 57 57 57 6 1625 N N N 28778...

Страница 14: ...or the mode with this function 9 10 7 Up down swing interface 8 Feedback interface of indoor unit 11 12 13 Interface of tube temperature sensor Wired controller only for the mode with this function 14...

Страница 15: ...Reactor 1 4 Chassis electric heating only for the mode with this function 5 6 4 way valve 7 Terminal of outdoor fan 8 Grounding wire 9 Communication wire 10 Neutral wire 11 Live wire 12 Interface of...

Страница 16: ...6 Function and Control 6 1 Remote Controller Introduction of RC08A 13...

Страница 17: ...makes the room cooler fan The air conditioner circulate the air COOL DRY HEAT SLEEP Press this button to turn the SLEEP mode ON or OFF For the detail see SLEEP MODE function description PRECAUTIONS b...

Страница 18: ...ed in the air conditioner Press the remote control I FEEL button to activate the temperature sensor placed in the remote control This function is designed to provide a personalised environment by tran...

Страница 19: ...s low frost or ice may appear on the heat exchanger coil reducing the heating performance When this happens a microcomputer defrosting system operates At the same time the fan in the indoor unit stops...

Страница 20: ...LAY SHOWS THE SELECTED TEMPERATURE NOTE Use DRY operation when you want to reduce the humidity in the room Once the room temperature reaches the set level the unit repeats the cycle of turning on and...

Страница 21: ...ssing both buttons again the remote control will be released from its locked position I FEEL ROOM TE MP FUNCTION OPERATION LOCK FUNCTION SETTING THE TIMER The timer can be selected by pressing TIMER O...

Страница 22: ...utlet and drip off Do not move the flap with your hands when the air conditioner is running Use the button on the remote control to adjust the position of the flap If you move the flap by hand the fac...

Страница 23: ...checking and maintenance 2 The air condition must apply specialized circuit and prohibit share the same circuit with other appliances 3 The air conditioner should be installed in suitable location and...

Страница 24: ...e there may be leaked corrosive gas or flammable gas If there leaked gas around the unit it may cause explosion and other accidents 7 Do not use extension cords for electrical connections If the elect...

Страница 25: ...a The naked flame is prohibited in the maintenance area and the no smoking warning board should be hanged Check whether the appliance mark is in good condition Replace the vague or damaged warning mar...

Страница 26: ...Electronic leakage detector 10 Pipe pliers pipe cutter 2 Screw driver 5 Universal meter 8 Vacuum pump 11 Pipe expander pipe bender 3 Impact drill drill head electric drill 6 Torque wrench open end wre...

Страница 27: ...t 50cm At least 30cm At least 300cm At least 200cm Space to the floor Space to the obstruction Space to the obstruction Space to the obstruction Space to the ceiling Space to the obstruction Space to...

Страница 28: ...the bound pipes pass through the wall hole and then connect outdoor unit Neaten the pipes Vacuum pumping and leakage detection Check after installation and test operation Finish installation Note this...

Страница 29: ...conditioner Air switch capacity 2 Grounding Requirement 1 The air conditioner is first class electric appliance It must be properly grounding with specialized grounding device by a professional Please...

Страница 30: ...tly downward to the outdoor side with the gradient of 5 10 As show in Fig 2 Note Insulating pipe Torque wrench Open end wrench Indoor pipe Pipe Union nut Union nut Pipe joint Pipe Hex nut diameter mm...

Страница 31: ...ing them When binding to a certain degree separate the indoor power and then separate the drain hose As show in Fig 15 3 Bind them evenly 4 The liquid pipe and gas pipe should be bound separately at t...

Страница 32: ...d Outdoor Pipes 1 Remove the screw on the right handle of outdoor unit and then remove the handle As show in Fig 21 2 Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe As s...

Страница 33: ...f there is leakage with leakage detector 2 With soap water If leakage detector is not available please use soap water for leakage detection Apply soap water at the suspected position and keep the soap...

Страница 34: ...Communi cation Malfunction E6 During cooling operation compressor stops while indoor fan motor operates During heating operation the complete unit stops Refer to the corresponding malfunction analysi...

Страница 35: ...utdoor condenser temperature sensor is open short circuited F4 During cooling and drying operation compressor stops while indoor fan will operate During heating operation the complete unit will stop o...

Страница 36: ...igher than 265VAC turn on the unit after the supply voltage is increased to the normal range 2 If the AC input is normal measure the voltage of electrolytic capacitor C on control panel AP1 if its nor...

Страница 37: ...t will stop Replace outdoor control panel AP1 30 Module high temperature protection P8 During cooling operation compressor will stop while indoor fan will operate During heating operation the complete...

Страница 38: ...alfunction or system blocked or the connector loosed 37 power protection L9 compressor stop operation and Outdoor fan motor will stop 30s latter 3 minutes latter fan motor and compressor will restart...

Страница 39: ...is malfunction occurs during heating operation the complete unit will stop operation 1 Supply voltage is lower than AC175V 2 Wiring terminal 4V is loosened or broken 3 4V is damaged please replace 4V...

Страница 40: ...h refrigrant blockage of capillary and increase of suction temp improper running of compressor burning in or stuck of bearing damage of discharge valve malfunction of protector Processing method adjus...

Страница 41: ...agnosis process Is the wiring terminal between the temperature sensor and the controller loosened or poorly contacted Start Insert the temperature sensor tightly Yes Yes Yes Yes Yes Yes No No No No No...

Страница 42: ...control terminal is firm Turn on the unit again measure whether the output voltage on control terminal for PG motor is more than 50V within 1 min after the louvers are opened Tighten the screw reasse...

Страница 43: ...abnormal Malfunction diagnosis process Start Is there jumper cap on the mainboard Is the jumper cap inserted correctly and tightly Replace the jumper cap with the same model Appearance of the jumper...

Страница 44: ...ross detectioncircuit of the mainboard is defined abnormal Malfunction diagnosis process Turn power off for 1minute the turn back on The unit returns to normal Conclusion U8 is displayed due to power...

Страница 45: ...etecting plate WIFI JF Start Is malfunction eliminated The end check if the connection wire are correctly connected Replace the detecting plate with the same model Replace the mainboard with the same...

Страница 46: ...he voltage testing circuit on control panel AP1 Replace the control panel AP1 Measure the AC voltage between terminalL andN on wiring board XT power supply Voltage within 210VAC 250VAC Shut down the p...

Страница 47: ...ding to the electric wiring diagram and then turn on the unit Check the connection between the control board and the compressor by referring to the electric wiring diagram Check whether wires of compr...

Страница 48: ...ction Is outdoor ambient temperature higher than 53 20 minutes after the complete unit is powered off Is heat dissipation of the indoor unit and outdoor unit abnormal Normal protection please operate...

Страница 49: ...Fault diagnosis process No Yes No No Yes Yes Yes No Power on the unit Is stop time of the compressor longer than 3 minutes Restart it up after 3 minutes Does startup fail Are the wires for the compre...

Страница 50: ...Is connection sequence right Is the connection made in clockwise direction Connect the wires correctly Replace the control panel AP1 If the fault is eliminated Replace the compressor End Out of step o...

Страница 51: ...unit is powered off Is the terminal FA for the electronic expansion valve connected correctly Connect the wires correctly Resistances between the first four pins close to the terminal hole and the fif...

Страница 52: ...normally before the failure occurs The AP1 voltage detection circuit is at fault Check wiring inside of the indoor and outdoor units Are wires broken Check the communication circuit of the outdoor uni...

Страница 53: ...e mainboard with the same model End Is the supply voltage too low with overload Is the indoor outdoor heat exchanger dirty or are the air inlet and outlet blocked The fan is abnormal Fan speed is too...

Страница 54: ...of compressor Compressor can t operate Refer to point 5 of maintenance method for details 9 3 Troubleshooting for Normal Malfunction 1 Air Conditioner Can t be Started Up 2 Poor Cooling Heating for A...

Страница 55: ...apping is not tight Water leaking from the pipe connection place of indoor unit Wrap it again and bundle it tightly 5 Compressor Can t Operate Possible causes Discriminating method air conditioner sta...

Страница 56: ...louver Bend the horizontal louver with hand and then separate the horizontal louver from the crank shaft of step motor to remove it Separate the panel rotation shaft from the groove fixing the front...

Страница 57: ...ssy is different for different models Loosen the connection clasps between front case sub assy and bottom case Lift up the front case sub assy and take it out Screw off the 2 screws that are locking t...

Страница 58: ...cover top cover big handle valve cover Before disassamble Remove the screws fixing big handle valve cover and then remove them Remove the screws fixing top panel and then remove the top panel AW YHDL0...

Страница 59: ...Remove connection screws connecting the front panel with the chassis and the motor support and then remove the front panel Remove the screws fixing protective grille and then remove the protective gr...

Страница 60: ...the screws fixing motor support and then remove the motor support Remove the screws fixing clapboard and then remove the clapboard Remove the screws fixing electric box assy cut off the tieline pull o...

Страница 61: ...with capillary and condenser unsolder the welding joint connecting the gas valve and air return pipe remove the 2 screws fixing the gas valve to remove the gas valve Unsolder the welding joint connec...

Страница 62: ...Conversion formula for Fahrenheit degree and Celsius degree Tf Tcx1 8 32 Ambient temperature Fahrenheit display temperature Fahrenheit Celsius Fahrenheit display temperature Fahrenheit Celsius Fahren...

Страница 63: ...ip Confirm the pipe length according to the distance of indoor unit and outdoor unit Cut the required pipe with pipe cutter B Remove the burrs Remove the burrs with shaper and prevent the burrs from g...

Страница 64: ...0 737 5 63 46 34 10 2 73 2 358 112 0 717 4 60 23 35 9 779 74 2 28 113 0 697 3 57 18 36 9 382 75 2 206 114 0 678 2 54 31 37 9 003 76 2 133 115 0 66 1 51 59 38 8 642 77 2 064 116 0 642 0 49 02 39 8 297...

Страница 65: ...5 84 61 34 13 59 73 3 144 112 0 956 4 80 31 35 13 04 74 3 04 113 0 93 3 76 24 36 12 51 75 2 94 114 0 904 2 72 41 37 12 76 2 844 115 0 88 1 68 79 38 11 52 77 2 752 116 0 856 0 65 37 39 11 06 78 2 663...

Страница 66: ...11 32 101 3 22 15 362 9 24 51 41 63 10 93 102 3 13 14 342 8 25 49 19 64 10 54 103 3 04 13 323 9 26 47 08 65 10 18 104 2 96 12 306 2 27 45 07 66 9 83 105 2 87 11 289 6 28 43 16 67 9 49 106 2 79 10 274...

Страница 67: ...Consult with the sales agency or manufacturer for details ATTENTION Le design et les donn es techniques sont donn s titre indicatif et peuvent tre modifi s sans pr avis AIRWELL RESIDENTIAL SAS 10 Rue...