5. Dilute the antifreeze solution in accordance with the manufacturer’s instruc-
tions.
6. Open all water faucets.
7. Insert hose length into the antifreeze container, turn the pump switch on,
and run the water pump until the antifreeze solution fills all water lines. Flush
toilet. Work hand shower spray while holding down in tub.
8. Shut off the pump and close all faucets.
9. Disconnect the hose length from pump inlet fitting and reconnect water
system inlet line.
Water Heater Bypass (except 30’ Model)
For Normal Operation
Turn water heater by-pass valves to normal flow position. Shut off valve B -
open valves A and C.
For Winterizing (bypass position) close valves A and C, open valve B.
By-pass valve locations:
19 Ft. Bambi and the 23 Ft.- under the corner bed, accessible from holes in the
bed top under the mattress.
20 Ft. - under roadside front dinette seat, remove the seat cushion and there
are holes in the seat base for access.
23 Ft. Front Bed - inside the removable bedroom wardrobe cabinet lower face
panel. The panel is held on by two pressure catches and can be removed by
pulling straight out on the panel.
25 Ft. front bed - through the curbside front exterior access door.
27 Ft. front bed - under bathroom lavatory. Open the lavatory cabinet door to
access a drop down door. Open the drop down door to access the valves on
the water heater.
28 Ft. - under the front lounge on the roadside. An access hole is provided in
the lounge top.
HOT WATER LINE
COLD WATER LINE
BYPASS
LINE
WATER
HEATER TOP
A
B
C
Cold
Water Inlet
Hot
Water Outlet