En-2

(9)  Intake grille

(10)  Front panel

(11)  Air 

fi

 lter

(12)  Vertical air

fl

 ow direction louver

(13)  Horizontal air

fl

 ow direction louver (behind Air

fl

 ow Direction Louver 

and Damper)

(14)  Damper
(15)  Air cleaning 

fi

 lter

(16)  Rope
(17)  Drain Hose

Control unit (optional)

Types of remote controllers:

 

Wireless remote controller

 

Wired remote controller

 

Simple remote controller

For operation method, please refer to the Operating Manual of each 
device.

MANUAL AUTO OPERATION

Use the MANUAL AUTO operation in the event the remote control unit is 
lost or otherwise unavailable.

 CAUTION

Do not press the MANUAL AUTO button with wet hands or pointed ob-
jects, otherwise an electric shock or malfunction may occur.

Starting Operation

Press the MANUAL AUTO button on the operating 
control panel.

The operation can be set in the following setting.

Operating mode

AUTO:
When Auto mode cannot be selected, it will 
operate in the same mode as the other indoor 
unit in the same system. (When other indoor 
unit in the same system doesn’t operate, the air 
conditioner will operate in cooling.)

Fan speed

AUTO

Setting temperature

23 °C

Stopping Operation

Press the MANUAL AUTO button on the operating 
control panel.

AIRFLOW DIRECTION

Vertical air

fl

 ow direction

The vertical wind direction can 
be controlled with the remote 
controller.

1

2

3

4

Cooling, Dry 
and Heating

Horizontal air

fl

 ow direction

The horizontal air

fl

 ow direction can be manually set by adjusting horizon-

tal air

fl

 ow direction louvers.

 CAUTION

Always adjust the horizontal air

fl

 ow direction louvers when the damper 

is open. Opening the damper forcibly with hands can cause damper to 
malfunction.

AIR OUTLET SELECTION

With this function , air come out simultaneously from the upper and lower 
air outlets so that the room can be cooled or heated effectively. This 
function is set using the switch behind the front grille of the Indoor unit. 
(This function is available in cooling and heating operation.)

How to set the out air outlet

Upper air outlet only

Upper and lower air outlets

Set the air outlet 
selection switch to 

Set the air outlet 
selection switch to 

Air blows out automatically from 
the upper and lower air outlets as 
shown in the table below.

NOTES:

Set the air outlet selection switch to the end. Otherwise, air outlet cannot 
be selected as intended.

Description of operation
(When set to the upper and lower air outlets)

Cooling mode

Dry mode

Heating mode

Upper and 
lower air

fl

 ow

Upper air

fl

 ow

Upper air

fl

 ow 

only

Upper and 
lower air

fl

 ow

Upper air

fl

 ow

Room temper-
ature and set 
temperature 
are different.

Room tem-
perature is 
close to set 
temperature, 
or the air 
conditioner has 
operated for 1 
hour.

Air

fl

 ow 

temperature is 
high.

Air

fl

 ow tem-

perature is low.
(During 
defrosting 
operation, start 
of operation, 
etc.)

9382567019-02_OM.indb   2

9382567019-02_OM.indb   2

5/2/2017   8:55:23 AM

5/2/2017   8:55:23 AM

Содержание AGHA004GCAH

Страница 1: ...wahren Sie dieses Handbuch f r eine sp tere Bezugnahme auf MANUALE DI ISTRUZIONI UNIT INTERNA Tipo da pavimento Conservare questo manuale per consultazione futura KULLANIM KILAVUZU N TE Yer tipi Bu k...

Страница 2: ...the correct way The instructions in this section all relate to safety be sure to maintain save operating conditions WARNING and CAUTION have the following meanings in these instructions WARNING This...

Страница 3: ...and Heating Horizontal airflow direction The horizontal airflow direction can be manually set by adjusting horizon tal airflow direction louvers CAUTION Always adjust the horizontal airflow direction...

Страница 4: ...rity state When the other indoor units within the same system operate in heating mode cooling and dry mode can not be selected at the same time Standby state The standby state activates when 2 or more...

Страница 5: ...should be cleaned every two weeks When used for extended periods the unit may accumulate dirt inside reducing its performance We recommend that the unit be inspected regularly in addition to your own...

Страница 6: ...rily stop to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor unit s fan will stop If you w...

Страница 7: ...mell SPECIFICATIONS MODEL AG A004 GCAH AG A007 GCAH AG A009 GCAH AG A012 GCAH AG A014 GCAH POWER SOURCE 220 240V 50Hz 230V 60Hz AVAILABLE VOLTAGE RANGE 198 to 264 V 50Hz 198 to 253 V 60Hz COOLING CAPA...

Страница 8: ...9382567019 02_OM indb 7 9382567019 02_OM indb 7 5 2 2017 8 55 28 AM 5 2 2017 8 55 28 AM...

Отзывы: