background image

En-1

 

Do not operate the air conditioner with wet hands.

 

Check the condition of the installation stand for damage.

 

Operate only with air 

fi

 lters installed.

 

Do not drink the water drained from the air conditioner.

 

Do not apply any heavy pressure to radiator 

fi

 ns.

 

Do not use in

fl

 ammable gases near the air conditioner.

 

Do not touch the piping during operation.

 

Ensure that any electronic equipment is at least 1 m away from either 
the indoor or outdoor units.

 

This appliance is not intended for use by persons (including children) 
with reduced physical, sensory or mental capabilities, or lack of ex-
perience and knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person responsible for 
their safety. Children should be supervised to ensure that they do not 
play with the appliance.

Note:

 

Switching the operating mode in the heat recovery system may require 
some time to prepare for operation. Please note that this is not a fault.

PRECAUTIONS ON INSTALLATION

 CAUTION

 

Do not attempt to install this air conditioner by yourself.

 

This unit contains no user-serviceable parts. 
Always consult authorized service personnel for repairs.

 

When moving, consult authorized service personnel for disconnection 
and installation of the unit.

 

The unit must be grounded.

 

Make sure drain work is implemented properly for drainage.

 

Avoid installing the air conditioner near a 

fi

 replace or other heating 

apparatus.

 

When installing the indoor and outdoor unit, take precautions to pre-
vent access to infants.

NAME OF PARTS

(5)

(14)

(17)

(13)

(11) (10)

(9)

(12)

(6)

(7)

(8)

(3)

(2)

(1)

(4)

(16)

(15)

(1)  Operating control panel
(2)  Air outlet selection switch
(3)  MANUAL AUTO button: This is used to operate it while remote 

controller is not available.

(4)  Indicator lamps
(5)  TIMER Indicator Lamp (orange): It lights on while timer is working.
(6)  OPERATION Indicator Lamp (green): It lights on while operating.
(7)  FILTER Indicator Lamp (red): It lights on if the 

fi

 lter became dirty. 

Clean the 

fi

 lter referring to "CLEANING AND CARE". It lights off 

when RESET button is pressed after cleaning.

(8)  Remote Control Signal Receiver: This is the place to receive the 

signals from the remote controller.

SAFETY PRECAUTIONS

 

Before using the appliance, read these “PRECAUTIONS” thoroughly 
and operate in the correct way.

 

The instructions in this section all relate to safety; be sure to maintain 
save operating conditions.

 

“WARNING” and “CAUTION” have the following meanings in these 
instructions:

 WARNING

This mark indicates procedures which, if im-
properly performed, might lead to the death or 
serious injury of the user.

 CAUTION

This mark indicates procedures which, if im-
properly performed, might possibly result in per-
sonal harm to the user, or damage to property.

PRECAUTIONS ON USE

 WARNING

 

Do not keep exposing oneself to the direct wind of air conditioner for a 
long time.

 

Do not insert 

fi

 ngers or objects into the outlet port or intake grilles.

 

Except for EMERGENCY, never turn off main as well as sub breaker 
of the indoor units during operation. It will cause compressor failure as 
well as water leakage.
First, stop the indoor unit by operating the control unit, converter or 
external input device and then cut the breaker.
Make sure to operate through the control unit, converter or external 
input device.

 

If the power supply cord of this appliance is damaged, it should only 
be replaced by the authorized service personal, since special purpose 
tools and speci

fi

 ed cord are required.

 

If any refrigerant happens to leak, extinguish any 

fl

 ames, ventilate the 

room and get in touch with authorized service personnel. 

 CAUTION

 

Provide occasional ventilation during use.

 

Do not use in applications involving the storage of foods, precision 
equipment, or art works.

 

Do not place animals or plants in the direct path of the air

fl

 ow.

 

Do not direct air

fl

 ow at 

fi

 replaces or heating apparatus.

 

Do not block or cover the inlet port and outlet port.

 

Do not climb on, or place objects on, the air conditioner.

 

Do not set 

fl

 ower vases or water containers on top of air conditioners.

 

Do not hang objects from the indoor unit.

 

Do not place anything below the indoor unit that should not get wet.

 

Always turn off the electrical breaker whenever cleaning the air condi-
tioner or the air 

fi

 lter.

 

Do not pour water or cleaning solvent on the unit directly, or wash the unit with them.

 

Do not expose the air conditioner directly to water.

OPERATING MANUAL

PART NO. 9382567019-02
VRF system indoor unit (Floor type)

CONTENTS

SAFETY PRECAUTIONS ....................................................................... 1
NAME OF PARTS .................................................................................. 1
MANUAL AUTO OPERATION ............................................................... 2
AIRFLOW DIRECTION .......................................................................... 2
AIR OUTLET SELECTION ..................................................................... 2
OPERATING TIPS ................................................................................. 3
CLEANING AND CARE.......................................................................... 3
TROUBLESHOOTING ........................................................................... 5
SPECIFICATIONS .................................................................................. 6

9382567019-02_OM.indb   1

9382567019-02_OM.indb   1

5/2/2017   8:55:23 AM

5/2/2017   8:55:23 AM

Содержание AGHA004GCAH

Страница 1: ...wahren Sie dieses Handbuch f r eine sp tere Bezugnahme auf MANUALE DI ISTRUZIONI UNIT INTERNA Tipo da pavimento Conservare questo manuale per consultazione futura KULLANIM KILAVUZU N TE Yer tipi Bu k...

Страница 2: ...the correct way The instructions in this section all relate to safety be sure to maintain save operating conditions WARNING and CAUTION have the following meanings in these instructions WARNING This...

Страница 3: ...and Heating Horizontal airflow direction The horizontal airflow direction can be manually set by adjusting horizon tal airflow direction louvers CAUTION Always adjust the horizontal airflow direction...

Страница 4: ...rity state When the other indoor units within the same system operate in heating mode cooling and dry mode can not be selected at the same time Standby state The standby state activates when 2 or more...

Страница 5: ...should be cleaned every two weeks When used for extended periods the unit may accumulate dirt inside reducing its performance We recommend that the unit be inspected regularly in addition to your own...

Страница 6: ...rily stop to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor unit s fan will stop If you w...

Страница 7: ...mell SPECIFICATIONS MODEL AG A004 GCAH AG A007 GCAH AG A009 GCAH AG A012 GCAH AG A014 GCAH POWER SOURCE 220 240V 50Hz 230V 60Hz AVAILABLE VOLTAGE RANGE 198 to 264 V 50Hz 198 to 253 V 60Hz COOLING CAPA...

Страница 8: ...9382567019 02_OM indb 7 9382567019 02_OM indb 7 5 2 2017 8 55 28 AM 5 2 2017 8 55 28 AM...

Отзывы: