  If  there  is  perspiration  on  the  forehead  wipe  the  area  dry  before  taking  a 

temperature measurement.

 

Do  not  take  temperature  readings  on  areas  where  scars  or  skin  disorders 
(eczema, dermatitis, etc) are evident. 

 

During  temperatures  measurement  it  is  important  that  patients  remain  still. 
Movement  during  the  measurement  procedure  can  result  in  an  inaccurate 
reading.

 

Temperature measurements vary according to the measurement site. If several 
readings  are  taken  consecutively  at  different  points  on  the  forehead  the 
manufacturer recommends accepting the highest reading as correct.

 

If consecutive readings are to be taken, please wait 5 seconds between readings 
to  ensure  the  thermometer  resets  itself.  Also  ensure  that  the  thermometer 
maintains  a  2cm  -  3cm  distance  from  the  temple  while  the  reading  is  being 
taken,  otherwise  room  temperature  will  be  combined  into  the  measurement 
and provide inaccurate readings.

Once the measurement is completed, the LCD screen illuminates and the result is displayed, 
on either a green or a red background. The recorded body temperature is automatically 
stored in memory.

A recorded body temperature, displayed on a green illuminated screen indicates the result 
is inside the thermometer’s operational range of 22°C - 37.9°C (71.6°F - 100.2°F).

A recorded body temperature, displayed on a red illuminated screen indicates the result is 
outside the above range. If the recorded body temperature is between 38°C and 42.5°C 
it will display on a red illuminated screen. If it is above 42.5°C it will display on the red 
illuminated screen as only the 

 symbol. If it is below 22°C it will display on the red 

illuminated screen as only the 

 symbol. 

In  object  mode,  an  illuminated  red  screen  displays  when  the  thermometer,  records  a 
temperature outside its operating temperature range of 10°C - 80°C (50°F - 176°F). 

!

 

The thermometer should be stored at 15°C - 40°C (59°F - 104°F) to be within 
its operating temperature range. If the thermometer’s temperature is outside 
this temperature range the 

 icon will display. Allow the thermometer 30 

minutes to equilibrate with room temperature before use.

Содержание LifeTemp Radient AI-RADTH

Страница 1: ...ll operational and safety information This manual contains important information for the safe and effective use of the Airssential LifeTemp Radient Non Contact Thermometer Keep this manual in a safe place for future reference If you do not understand any part of these instructions contact the Airssential Customer Care Centre on 02 9708 5560 V 3 17 07 ...

Страница 2: ...nt Completion Sound 7 Using the LifeTemp Radient Non Contact Thermometer 7 Measuring Body Temperature 7 Normal Body Temperature 9 Measuring Object Temperature 9 Recalling Stored Measurements 10 LCD Display and Measurement Error Messages 10 Cleaning and Storage 11 Device Certifications 12 Disposal 13 Warranty and Service 13 Technical Specifications 14 Symbols Used In This Manual 15 Appendix 1 Elect...

Страница 3: ...ty to store up to 32 measurements in memory The LifeTemp Radient Thermometer can be conveniently used for recording either body or ambient surface temperatures like the temperature of bath water or an infant s feeding bottle and is Bisphenol A BPA free eliminating any potential health concerns associated with this chemical during the device s use Statement of Intended Use The LifeTemp Radient Non ...

Страница 4: ...d Report anything missing or damaged to the point of purchase Retain carton and packing materials for use in shipping or storing the thermometer Caution This product contains batteries which may be hazardous to small children Do not let small children handle this product Identification of the Thermometer s Parts Essential parts of the thermometer are described in Figure 1 FigurE 1 LCD Display Soun...

Страница 5: ...s instruction manual 2 This thermometer is unsuitable for use in the presence of flammable anaesthetics or oxygen 3 The thermometer should be stored at an ambient temperature between 15 C 40 C 59 F 104 F and be protected from direct sunlight dust and pollutants If the thermometer is not stored within the specified ambient temperature range allow the thermometer 30 minutes to equilibrate with room ...

Страница 6: ...hermometer Caution This product contains batteries which may be hazardous to small children Do not let small children handle this product Setting Thermometer Parameters Starting the Thermometer To activate the thermometer briefly press the or button The thermometer will perform a self test routine and display all digital segments on the LCD screen Within two seconds the display changes to show thr...

Страница 7: ...in this setting change The measurement completion sound will be restored to on when the thermometer is next activated Using the LifeTemp Radient Non Contact Thermometer Measuring Body Temperature Start the thermometer by pressing either the or button The thermometer always starts in body temperature mode as confirmed by the baby face icon in the top left hand corner of the LCD screen With the ther...

Страница 8: ...e LCD screen illuminates and the result is displayed on either a green or a red background The recorded body temperature is automatically stored in memory A recorded body temperature displayed on a green illuminated screen indicates the result is inside the thermometer s operational range of 22 C 37 9 C 71 6 F 100 2 F A recorded body temperature displayed on a red illuminated screen indicates the ...

Страница 9: ...fficulty in swallowing ear tugging rash etc As temperature varies according to the site used to take the measurement readings taken from different body sites cannot be directly compared Measuring Object Temperature Press the or button to start the device As the thermometer always starts in the body temperature setting press the button and the thermometer will switch to object temperature mode The ...

Страница 10: ...ure mode LCD Display and Measurement Error Messages The table below provides a summary of error messages and their meanings that may occur during the use of this thermometer Error Message Problem Solution The temperature of the device is outside its operating range Operating temperature for this device is 15 C 40 C 59 F 104 F The temperature of the measuring point is above the measurement range De...

Страница 11: ...ne etc or abrasive cleaners Never splash or soak this thermometer in any liquid including water 2 Ensure no debris from the swab remains in the probe aperture after cleaning Do not insert any foreign objects inside the probe aperture as this may scratch or damage the sensor and cause it to malfunction 3 The thermometer should be stored at an ambient temperature between 16 C 40 C 60 8 F 104 F and b...

Страница 12: ...etic Compatibility Requirements and Tests EN 60601 1 4 1996 A1 19M Medical electrical equipment Part 1 4 General Requirements for Safety Collateral Standard Programmable Electrical Medical Systems EN 12470 5 2003 Clinical Thermometers Part 5 Performance of Infrared ear thermometers EN 980 2008 Graphical Symbols for use in the Labelling of Medical Devices EN 1041 2008 Information supplied by the ma...

Страница 13: ...e warranty period provided the product has been used in accordance with the instructions If the product is no longer available replacement may be made with a similar product Airssential shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty This warranty excludes the repair or replacement of parts due to normal wear damage due to imp...

Страница 14: ...e Selection Body temperature Object temperature Memory Capacity Automatic storage for up to 32 body temperature results Sound Button Sound Measuring Sound and Result Sound Sound can be activated or deactivated by alternately pressing the Sound Button Screen Liquid Crystal Display mono LCD Display Icons Body or Object Temperature Mode Memory Location Temperature Reading C or F Low Battery Warning H...

Страница 15: ... internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR 11 Class A The thermometer is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Harmonic emissio...

Страница 16: ... range b Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular...

Страница 17: ... quality should be that of a typical commercial or hospital environment Interruptions and voltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec Not applicable Mains power quality should be that of a typical commercial or hospital environment If the user of the TH8xyz...

Страница 18: ...smitter W Separation distance according to frequency of transmitter M 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the ...

Страница 19: ...19 LifeTemp Radient Non Contact Thermometer ...

Страница 20: ...Airssential Home Health Care Solutions is a division of Boian Surgical Pty Ltd Airssential LifeTemp and Radient are the registered trademarks of Boian Surgical Pty Ltd These products are distributed under a quality management system certified as complying with ISO9001 2008 www airssential com au HuBDIC Co Ltd Korea MADE IN KOREA ...

Отзывы: