4.2

 

Wall Mount 

The following describes the Wall mounting procedure: 

1.

 

Select the required location where the AirVelocity unit is to be installed on the wall. 

 

2.

 

Utilize the mounting bracket and position it against the wall where the unit is to be 
mounted. Position with the Arrow symbol pointing up. Be sure to position the mounting 
bracket 

straight and level mounting to ensure the unit sits level.

 

3.

 

Mark the holes positions carefully through the mounting bracket onto the wall. See 

Figure 

11

. 

4.

 

Drill the four (4) holes. After drilling insert wall plugs (x4) (not included). 

 

Wall plugs (x4) and necessary hardware are not supplied by Airspan and are the 
responsibility of the installer. Use appropriate wall plugs according to field conditions. 

5.

 

Position the back bracket on the wall and drive the screws into inserted plugs, as shown 
below: 

Figure 15: Fix Mounting Bracket on Wall 

 

6.

 

Lift and carefully align and position the unit (verify that the 4 screws already inserted) so 
that the protruding screw heads engage the key-hole slots on the mounting bracket. 

Figure 16: Mount Unit on Mounting Bracket 

 

Содержание AIRVELOCITY 2700

Страница 1: ...ht by Airspan Networks Ltd 2021 All rights reserved worldwide AIRVELOCITY 2700 5G SUB 6HZ 4T4R IN D O O R RA D IO UN IT Installation Guide Document Part Number DUG01251 Document Revision A3 Published April 2021 ...

Страница 2: ...works Ltd does not make any representations and gives no warranties of whatever nature in respect of these documents including without limitation the accuracy or completeness of any information facts and or opinions contained therein No responsibility is assumed by Airspan Networks Ltd for the use of the documents nor for the rights of third parties which may be effected in any way by the use ther...

Страница 3: ...Directive 2014 53 EU 4 Warning Symbols 4 Service Information 4 About This Document 5 Purpose 5 Intended Audience 5 Document Conventions 5 Related Reading 5 1 Introduction 6 1 1 AirVelocity 2700 5G Sub 6Hz 6 2 Getting Started 7 2 1 AirVelocity 2700 Job Sheet 7 3 Verifying Prerequisites 8 3 1 Verifying Site Requirements 8 3 2 Verify Installation Requirements 8 4 AirVelocity 2700 5G Sub 6 Installatio...

Страница 4: ...13 Figure 9 M3X6 Locking Screw 13 Figure 10 Install Security Lock 14 Figure 11 Hole Spacing for Mounting Bracket 15 Figure 12 Fasten the Mounting Bracket to the Ceiling 15 Figure 13 Mounting AirVelocity Unit on the Mounting Bracket 16 Figure 14 Locking Screw M3X6 16 Figure 15 Fix Mounting Bracket on Wall 17 Figure 16 Mount Unit on Mounting Bracket 17 Figure 17 Fasten Unit on Mounting Bracket 18 Fi...

Страница 5: ...of the 5G NR standard and its place in the Airspan product suite This document is intended for qualified personnel with a working knowledge of 5G Revision History Revision Date Summary of Changes Created by Rev 0 1 December 2020 Initial document draft Comments MSF Rev 0 2 0 3 January 2021 Additions from comments MSF YS Rev A January 2021 Published MSF Rev A1 A2 January 2021 Modifications from comm...

Страница 6: ...dio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the technician is encouraged to try to correct the interference by performing one or more of the following measures Re orientate or relocate the u...

Страница 7: ... follow all operating and safety instructions 2 Static sensitive components inside do not remove the lid or base No user serviceable parts inside 3 Position the power cord to avoid possible damage do not overload circuits 4 Do not place this product on or near a direct heat source and avoid placing objects on the terminal 5 Use only a damp cloth for cleaning Do not use liquid or aerosol cleaners D...

Страница 8: ...d health effects that may result from exposure to electromagnetic fields Warning Symbols The following symbols may be encountered during installation or troubleshooting These warning symbols mean danger Bodily injury may result if you are not aware of the safety hazards involved in working with electrical equipment and radio transmitters Familiarize yourself with standard safety practices before c...

Страница 9: ...he following typographic conventions Table 1 Typographic Conventions Convention Element Blue underlined text Cross reference links Bold text Keyboard buttons and GUI elements Command Command names or phrases Computer output Text displayed by the computer Hyperlinks Website and e mail addresses Danger Signifies a hazardous situation if not avoided will cause death or serious injury Describes how to...

Страница 10: ...ion only and is subject for change without notice 1 1 AirVelocity 2700 5G Sub 6Hz The AirVelocity 2700 RU is a Radio Unit RU for 5G Radio Access Network RAN It is combined with additional RAN elements in order to provide a complete 5G mobile radio communication system The AirVelocity 2700 is based on open interfaces as defined by the O RAN alliance The fronthaul interface between the AirVelocity 2...

Страница 11: ...n Guide Copyright Airspan Networks Ltd 2021 P N DUG01251 Rev A3 Apr 2021 7 2 Getting Started 2 1 AirVelocity 2700 Job Sheet Plan the installation of the AirVelocity 2700 by using the Job Sheet which you can find as a removable job aid in Appendix A for this guide ...

Страница 12: ...e 2 Minimum Hardware Requirements Tool Use Philips screwdriver PH2 for securing the suspended ceiling bracket with M3X6 screws and safety screw after unit is attached to bracket Screwdriver wrench Appropriate tool for fastening bracket to ceiling or wall 3 2 2 Verify the Parts and Kits Verify your order and requirements to ensure the correct unit type is being installed Table 3 Parts Kits Installa...

Страница 13: ...ip Hardware 5 M3X6 screws AirVelocity External AC to DC Power Supply EU AV27 PSU ID AC EU 1 AC ADAPTER 150W IN 100 240VAC OUT 56VDC 2 679A Plug Type E OR AirVelocity External AC to DC Power Supply US AV27 PSU ID AC US 1 AC ADAPTER 150W IN 100 240VAC OUT 56VDC 2 679A Plug Type B OR AirVelocity External AC to DC Power Supply JP AV27 PSU ID AC JP 1 AC ADAPTER 150W IN 100 240VAC OUT 56VDC 2 679A Plug ...

Страница 14: ...P N DUG01251 Rev A3 Apr 2021 10 3 2 3 Physical Dimensions AirVelocity 2700 5G Sub 6 is in an indoor enclosure Table 4 AirVelocity 2700 5G Sub 6 Physical Dimensions Dimensions H x W x D Volume Weight 225 x 225 x 44mm 8 8 x 8 8 x 1 7 2 22l 1 65Kg 3 6 Lbs Figure 2 AirVelocity 2700 5G Sub 6 Physical Dimensions ...

Страница 15: ... locking 4 1 Ceiling Mount The following defines the AirVelocity 2700 ceiling mount assembly procedure for a suspended ceiling and a conventional ceiling Prior to assembly in any mounting scenario determine where the unit is to be installed 4 1 1 Suspended Ceiling Assembly 1 Determine the optimal position where the AirVelocity unit is to be installed at an intersection between the suspended ceilin...

Страница 16: ...asten the Mounting bracket ceiling clip onto the suspended ceiling s keel T bar Figure 5 Assemble the Mounting Bracket with the Clip onto the Keel T bar 5 Slide together the clip onto the suspended ceiling s T bar as shown below Figure 6 Tighten Clip to T bar 6 Fasten the clip with the 4 M3x6 screws as shown below Figure 7 Tighten the Screws ...

Страница 17: ... 13 7 Lift the AirVelocity 2700 5G Sub 6 into position and align the mounting screws supplied into the key holes on the underside of the mounting bracket as shown below 8 Slide unit to engage the key hole slots Figure 8 View from the Bottom 9 Insert the M3X6 screw to lock the unit onto the Mounting bracket Figure 9 M3X6 Locking Screw ...

Страница 18: ...y lock this is used both for anti theft and anti drop purposes Loop the other end of the Security cable to a secure riser Figure 10 Install Security Lock 11 Connect the necessary cables to the relevant ports see Cable Connections Fiber Ethernet port SFP 10GbE if applicable Copper Ethernet port ETH 10GbE if applicable Connect to power using a Phoenix Type Connector 2 Pole 5mm Pitch input range 42 5...

Страница 19: ...d holes on the mounting bracket onto the ceiling Figure 11 Hole Spacing for Mounting Bracket 5 After drilling holes and inserting approved ceiling anchors plugs fasten the mounting bracket to the ceiling with approved screws and washers not included Figure 12 Fasten the Mounting Bracket to the Ceiling 6 The mounting bracket is installed and ready for AirVelocity 2700 unit mounting Screws and washe...

Страница 20: ...Screw M3X6 9 After installation is completed install the Kensington Security lock this is used both for anti theft and anti drop purposes Fasten the other end of the Security cable to the ceiling using a screw plug into a secure area of the ceiling 10 Connect the necessary cables to the relevant ports see Cable Connections Fiber Ethernet port SFP 10GbE if applicable Copper Ethernet port ETH 10GbE ...

Страница 21: ...ure the unit sits level 3 Mark the holes positions carefully through the mounting bracket onto the wall See Figure 11 4 Drill the four 4 holes After drilling insert wall plugs x4 not included Wall plugs x4 and necessary hardware are not supplied by Airspan and are the responsibility of the installer Use appropriate wall plugs according to field conditions 5 Position the back bracket on the wall an...

Страница 22: ... Security cable to a secure connection on the wall 10 Connect the necessary cables to the relevant ports see Cable Connections Fiber Ethernet port SFP 10GbE if applicable Copper Ethernet port ETH 10GbE if applicable Connect to power using a Phoenix Type Connector 2 Pole 5mm Pitch input range 42 57vDC 4 3 Cable Connections 4 3 1 DC Cable Connection 1 Insert the power cable wires into the Phoenix Ty...

Страница 23: ...ED Display The two LEDs on the unit panel provide unit status indication When powering up refer to the following table for indication of current status Table 6 LED Display LED State Red Green Power Power On Flash Once Flash Once Startup Ongoing Off Off Hardware Error On Off Clock Locking N A Blink 1HZ Clock Locked N A On STATUS Power On Flash Once Flash Once Fronthaul Interface Linkdown Off Off Co...

Страница 24: ...t Site Requirements Area for installation identified Position on ceiling or wall identified Method of reaching ceiling wall positions ladders elevated work platform All equipment items available at the installation site AirVelocity 2700 5G Sub 6 unit Mounting bracket and required hardware Required cables Tool Requirements For further information see Verify the Tools Philips screwdriver securing sc...

Страница 25: ...allation Guide Copyright Airspan Networks Ltd 2021 P N DUG01251 Rev A3 Apr 2021 21 Table 8 Acronyms Abbreviations and Definitions Term Expansion LED Light Emitting Diode NR New Radio 5G Long Term Evolution RU Radio Unit UE User Equipment The end user in 5G ...

Страница 26: ...s a new issue and sends an issue number for your reference The system uses this issue number to categorize and store e mails under the appropriate issue To help Customer Care Help Desk identify your issue include the issue number and your Customer Care Helpdesk account details in all further communications Main Operations Airspan Communications Ltd Capital Point 33 Bath Road Slough Berkshire SL1 3...

Страница 27: ...Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interferen...

Отзывы: