AirVelocity 2700 5G Sub-6Hz
4T4R Indoor Radio Unit – Installation Guide
© Copyright Airspan Networks Ltd., 2021
P/N:
DUG01251
Rev. A3, Apr 2021
15
4.1.2
Conventional Ceiling Assembly
1.
Determine the optimal position where the AirVelocity unit is to be installed.
2.
Set aside the Ceiling clip (it is not needed for conventional ceiling assembly).
3.
Position the mounting bracket on the ceiling. Be sure to position the mounting bracket
straight
to ensure the unit sits as required.
4.
Mark the screw positions carefully through the provided holes on the mounting bracket onto the
ceiling.
Figure 11: Hole Spacing for Mounting Bracket
5.
After drilling holes and inserting approved ceiling anchors (plugs) fasten the mounting bracket to
the ceiling with approved screws and washers (not included).
Figure 12: Fasten the Mounting Bracket to the Ceiling
6.
The mounting bracket is installed and ready for AirVelocity 2700 unit mounting.
Screws and washers (x4) and any necessary hardware are not supplied by Airspan and are
the responsibility of the installer. Use appropriate ceiling hardware according to field
conditions.
7.
Lift the AirVelocity 2700 into position and align the mounting screws (supplied) into the key-
holes on the underside of the mounting bracket, as shown below: