AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186
Airspan Commercial and Internal Use
51
5.
Secure the wire ends of the power cable into the head part of the connector, as shown
below.
Figure 49: Plug pins
Figure 50: Pin assignment
Pin #
Wire Color
Description
1
White
Neutral
2
Black
Phase
3
Green
Ground
Figure 51: Attaching wires
6.
Insert into connector, the by alignment pin determines the correct orientation.
7.
Tighten the tail nut on to the body forcing the seal to compress around the power cable.
Caution:
Do not over tighten the connector or the tail nut. The nut should be tightened
to a torque of no more than 3.3 Nm (2.43 lb-ft) max.
Note:
When securing the cable verify there is no tension on the connector so that it is
easy to disconnect and re-connect for future maintenance actions.