AirHarmony-4400 (External Cavity Filters) Installation Guide
UGD-D01186
Airspan Commercial and Internal Use
50
Figure 45: AC Connector disassembled
2.
Strip back and remove the outer sheath to expose the inner black, white and green
insulated wires to a length of 3 cm (1.18 in). Then strip back 6 mm (0.24 in) of the inner
core insulation.
Figure 46: Strip wire
3.
Thread the 3 wire (stranded 18AWG) cable through the tail nut, gland seal, body and
rubber gasket of the connector casing as shown below. Do not tighten the tail nut.
Figure 47: power cable assembly
4.
Insert the stripped wire ends of the cable into the connector sleeves.
Figure 48: Connector on cable