11 Troubleshooting
11.1 Hardware OLED Errors
This section outlines the different strings on the oled display including their meaning and
troubleshooting.
11.1.1 Line 1
The first line of the oled display will indicate the state of the system. The possible states of the
system are
-
OK - System is booting
-
Ready - System is ready to start capturing
-
Lidar power down - Lidar sensor has been powered down, push button once to repower
lidar
-
Capturing
11.1.2 Line 2
The second line of the oled display shows the state of the lidar sensor. The possible states of
the lidar are
-
ERR Not connected
-
Lidar has not bridged a connection yet, this will occur on boot. Give the sensor
up to 2 minutes to make a connection on boot. This will also occur when the
sensor is powered down. If the issue persists for longer than 2 minutes contact
your distributor.
-
ERR No data yet
-
Lidar has made a connection, the lidar sensor has to spin up to the appropriate
speed before data can be read, this will take ~30 seconds.
-
ERR PPS Issue
-
Internal mismatch between lidar sensor and GNSS timestamp. This may occur
on boot especially if the GNSS receiver has not made a fix yet. Give this 30
seconds to clear. If the issue persists contact your distributor.
-
ERR Long Timesteps
-
Internal mismatch between lidar sensor and GNSS timestamp. This may occur
on boot especially if the GNSS receiver has not made a fix yet. Give this 30
seconds to clear. If the issue persists contact your distributor.
-
OK connected
-
Lidar is networked into the payload and is ready for the capture to start.
-
OK “######”
-
This occurs when the lidar is capturing data, this will show the number of points
that the lidar sensor has captured.