PAGE 14 OF 20
7.2.6 Temp. Sensor in condenser is open circuit or short circuit
Is the outdoor temperature
sensor
connector
and
connection good?
Repair the connector and
reconnect
Replace the sensor and
check if E5 display again?
NO
YES
Replace outdoor e-box
YES
Is the temp. more than 65°C ?
Is the temp sensor right according to the annex 1
Replace the outdoor main board
No
Yes
Replace the temp sensor