![AIROS AIROS 8 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/airos/airos-8/airos-8_operating-instructions-for-use-manual_2878699017.webp)
14
3.5
To set the Therapy Time, press UP
or DOWN
to scroll
to THERAPY TIME. Press SELECT to confirm. The therapy
time will begin blinking. Press UP
or DOWN
to scroll
to 15, 30, 45, or 60 minutes. Press SELECT to confirm. The
cycle time will be updated and stop blinking.
To select a chamber in which to skip pressure, press UP
or DOWN
to scroll to SKIP CHAMBER. Press SELECT to
confirm. The skip chamber setting will begin blinking. Press
UP
or DOWN
to scroll through the settings, including
OFF, 1, 2, 3, 4, 5, 6, 7, or 8. Press SELECT to confirm. The
skip chamber setting will be updated and stop blinking.
To operate an optional Lymphedema Preparation Treatment
(LPT) mode before Gradient Mode therapy, press UP
or
DOWN
to scroll to LPT MODE. Press SELECT to confirm.
The LPT Mode option will begin blinking. Press UP
or
DOWN
to scroll through the settings, including OFF,
CLEARING, and FOCAL.
If you select FOCAL THERAPY, proceed to 3.6.
If you select CLEARING THERAPY, proceed to 3.7.
If you do not wish to run an LPT Mode option, scroll to OFF.
Press SELECT to confirm. The LPT Mode setting will be
updated and stop blinking.
To go back to the MAIN MENU SCREEN, press UP
or
DOWN
to scroll to BACK TO MAIN MENU. Press SELECT
to confirm.
To begin treatment therapy, press UP
or DOWN
to
scroll to BEGIN TREATMENT. NOTE: If this is the first time
the device is being used, you may be asked to select the
number of sleeves to be used for therapy. Refer to 3.2 for
additional instructions.
If this is not the first time the device is being used, you may
not be asked to select the number of sleeves. Treatment will
begin immediately.
3.6
FOCAL THERAPY MODE
SET-UP SCREEN
To set the Pressure, press UP
or DOWN
to scroll to
PRESSURE. Press SELECT to confirm. The pressure will
begin blinking. Press UP
or DOWN
to choose from 40,
45, or 50 mmHg. Press SELECT to confirm. The pressure will
be updated and stop blinking.
To select the number of Chambers for therapy, press UP
or DOWN
to scroll to CHAMBERS. Press SELECT to
confirm. The pressure will begin blinking. Press UP
or
DOWN
to choose from 1-4, 2-5, 3-6, 4-7, or 5-8. Press
SELECT to confirm. The pressure will be updated and stop
blinking.
To set the Therapy Time, press UP
or DOWN
to scroll
to THERAPY TIME. Press SELECT to confirm. The pressure
will begin blinking. Press UP
or DOWN
to choose from
10 or 15 minutes. Press SELECT to confirm. The pressure will
be updated and stop blinking.
To exit and return to a therapy mode set-up screen, press
UP
or DOWN
to scroll to EXIT. Press SELECT to
confirm.
3.7
CLEARING THERAPY MODE
SET-UP SCREEN
To set the Pressure, press UP
or DOWN
to scroll to
PRESSURE. Press SELECT to confirm. The pressure will
begin blinking. Press UP
or DOWN
to choose from 15
or 20 mmHg. Press SELECT to confirm. The pressure will be
updated and stop blinking.
To exit and return to a therapy mode set-up screen, press
UP
or DOWN
to scroll to EXIT. Press SELECT to
confirm.
PREVIOUS
THERAPY TIME: 15 min
SAVE/EXIT
FOCAL THERAPY
PRESSURE: 40 mmHg
CHAMBERS: 1-4
MORE
CLEARING THERAPY
PRESSURE: 20 mmHg
SAVE/EXIT
Operating Instructions (continued)