To ensure your safety as well as the service life of your scale, please avoid using 

the scale under the following circumstances:

Concurrent use of this device and implantable medical electronic instruments, e.g. 

Cardiac Pacemaker
Concurrent use of this device and wearable medical electronic instruments, e.g. 

electrocardiograph
Concurrent use of this device and other medical electronic instruments for life support, 

e.g. mechanical heart
Slippery floor such as tile floor
Jumping onto the platform immediately after bath or with wet hands
Near a cell phone or microwave oven

Avoid storage in the following locations:

Where there is water
Where the device may be exposed to extreme temperatures, humidity, moisture, direct 

sunlight, dust, or salt air
Where there is risk of shock or drop
Where you store chemicals or full of corrosive gases
Where in reach of the infants or children 

Your Scale and Its Environment

Efficient Use of Your Scale

Safety Information

To ensure the accuracy of measurement, please follow below instructions when 

you start measurement.

Place the scale on a flat, hard surface. Soft surface such as carpet will affect the 

performance of the scale.
Step onto the platform with bare feet. Stand still and keep full contact with the electrodes 

until the measurement is complete.
Start measurement at least two hours after Getting up or Dinning.
Avoid measurement immediately after strenuous exercise, sauna or bath, drinking, and 

dinning.
Always start measurement in the same time slot and on the same scale located on the 

same flat, hard surface.

Safety Information

The warning signs and symbols are essential to ensure your correct and safe use of 

this product and protect you and others from injury. Please kindly find the meanings of the 

warning signs and symbols, which you may encounter in the label and user manual, as 

follows:

Safety and Usage Information

Symbol for “THE OPERATION 

GUIDE MUST BE READ”

Symbol for “MANUFACTURER”

Symbol for “COMPLIES WITH MDD 

93/42/ECC REQUIREMENTS”

Symbol for “ENVIRONMENT 

PROTECTION – Waste electrical 

products should not be disposed of with 

household waste. Please recycle where 

facilities exist. Check with your local 

authority or retailer for recycling advice”

The Bluetooth Combination Mark

Symbol for “SERIAL NUMBER”

Symbol for “DIRECT CURRENT”

Symbol for “INDOOR USE ONLY”

Symbol for “MANUFACTURE 

DATE”

Airon Body Analysis Scale LS 202-B offers you a seamless way to manage your health. Please 

be aware that this device is designed for adults’ self-measuring and self-monitoring body fat 

level. Any information provided by this device is in no way meant to treat, cure or prevent any 

disease or illness from happening. This device should not be used by anyone who is acutely or 

chronically ill, suffering from a disease or taking medications that affect your water levels. The 

accuracy of readings for these patients has not been verified. Specific medical advice should be 

obtained from a physician.

LS 202-B is equipped with data transmission function. It may emit electromagnetic energy so 

as to perform its intended function. Nearby portable and mobile RF communications equipment 

can affect the performance of LS 202-B.

Portable and mobile RF communications equipment can affect the measuring accuracy of LS 

202-B.

Kindly note that the use of accessories, transducers or cables other than those specified, with 

the exception of transducers and cables sold by the manufacturer as replacement parts for 

internal components, may result in increased EMISSIONS or decreased IMMUNITY of LS 202-B.

Be aware that misuse of electrical equipments can cause electric shock, burns, fire and other 

hazards.  

Warning that the LS 202-B should not be used adjacent to or stacked with other equipment.

Manufacturer will make available on request circuit diagrams, component parts list,etc.

WARNING: No modifications of this equipment is allowed.

During using the Analyzer, the patient will contact with the surface and the electrode of the 

Analyzer. The device doesn’t need to be calibrated in two years lifetime.

CAUTION

   This device is contraindicated for any female subject who may be suspected of, or is pregnant. 

Besides provided inaccurate readings, the affects of this device on the fetus are unknown. 

   This device is contraindicated for any person who is connected to a wearable or implantable 

electronic device or instrument such as a pacemaker or defibrillator.

INDICATIONS FOR USE

The Airon Body Analysis Scale measures weight and uses bio-electrical impedance analysis 

(BIA) technology to estimate body fat, total body water percentage, bone mass, and muscle 

mass in generally healthy adults 18 years of age or older. 

It is intended for use in the domestic setting only. 

Содержание LS 202-B

Страница 1: ...ysis Scale LS 202 B App name Airon Model LS 202 B www airon no AIRON AGENTURER AS vre Slottsgate 18 20 0157 Oslo NORWAY Tel 47 22 41 08 00 www airon no Airon Wireless products Airon Wireless system is...

Страница 2: ...the Batteries Install the App and Pair up Select Measurement Unit Start Measuring Daily Measurement Data Management Data Transmission Troubleshooting Error Prompt When Measuring When Data Transmittin...

Страница 3: ...for SERIAL NUMBER Symbol for DIRECT CURRENT Symbol for INDOOR USE ONLY Symbol for MANUFACTURE DATE Airon Body Analysis Scale LS 202 B offers you a seamless way to manage your health Please be aware t...

Страница 4: ...Batteries 1 5V each 3 User Manual Overview Overview Device Components Battery Compartment UNIT Button LCD Display Electrode Electrode Stone Pound Bioelectrical Impedance Analysis Kilogram Data transm...

Страница 5: ...ooth function in line with BLE Technical Specifications as well as BLP Protocol established by global organization Bluetooth SIG are capable to receive your personal health data Just simply install th...

Страница 6: ...suring Select Measurement Unit Daily Measurement With original SENSE ON patent technology LS 202 B B will automatically switch on as you step on the platform barefooted When your scale is successfully...

Страница 7: ...ocated on the soft ground such as a carpet OR on a rugged surface Please place the device on a flat hard surface Warm up your hands and feet to resume blood circulation and then measure again Cold bod...

Страница 8: ...Batteries not yet installed Worn batteries Low battery Install the batteries Please refer to Insert the Batteries Replace all four batteries in the same time Please purchase the authorized batteries...

Страница 9: ...in normal use for a period of TWO years from the date of retail purchase This warranty does NOT cover damages caused by misuse or abuse including but not limited to Failure caused by unauthorized rep...

Страница 10: ...21 1 24 24 20 20 1 29 29 1 32 32 16 1 23 23 1 26 26 22 22 1 30 30 1 33 33 14 4 14 70 63 15 21 63 57 22 24 57 55 25 55 37 4 20 70 58 21 29 58 52 30 32 52 49 33 49 37 16 50 59 17 1 24 24 1 27 27 23 23...

Страница 11: ...E EQUIPMENT and ME SYSTEMS that are not LIFE SUPPORTING Guidance and manufacturer s declaration electromagnetic immunity IMMUNITY test IEC 60601 TEST LEVEL Compliance level Electromagnetic environment...

Страница 12: ...Separation distance according to frequency of transmitter m Rated maximum output power of transmitter W 150 kHz to 80 MHz P V d 5 3 1 80 MHz to 800 MHz 800 MHz to 2 5 GHz 1 0 0 1 0 1 0 1 0 0 1 For tr...

Отзывы: