Airon LS 202-B Скачать руководство пользователя страница 2

1

Table of Contents

Safety Information

Safety and Usage Information
Your Scale and Its Environment
Efficient Use of Your Scale

Overview

Device Components
LCD Display

Initial Start-Up

General Instructions
Insert the Batteries
Install the App and Pair-up
Select Measurement Unit

Start Measuring

Daily Measurement

Data Management

Data Transmission

Troubleshooting

Error Prompt
When Measuring ...
When Data Transmitting...

Specifications
Maintenance
Warranty
Appendix

Table of Body Fat Level
Table of Body Water Level
Health Tips – About Body Fat
EMC Guidance

2
3
3
 
4

5

 
6

6

7
8

9

10
 
11
12
13
14
15
15

16
16
16
17-20

...............................................................................................

......................................................................................................

.................................................................................................................

.................................................................................................................

........................................................................................................

...................................................................................................................

.............................................................................................................................

....................................................................................................................

..................................................................................................................

....................................................................................................................

........................................................................................................

............................................................................................................................

...............................................................................................................................

.............................................................................................

......................................................................................................

.................................................................................................

.........................................................................................................................

..........................................................................................................

Table of Contents

..............................................................................................................................

...................................................................................................................

Содержание LS 202-B

Страница 1: ...ysis Scale LS 202 B App name Airon Model LS 202 B www airon no AIRON AGENTURER AS vre Slottsgate 18 20 0157 Oslo NORWAY Tel 47 22 41 08 00 www airon no Airon Wireless products Airon Wireless system is...

Страница 2: ...the Batteries Install the App and Pair up Select Measurement Unit Start Measuring Daily Measurement Data Management Data Transmission Troubleshooting Error Prompt When Measuring When Data Transmittin...

Страница 3: ...for SERIAL NUMBER Symbol for DIRECT CURRENT Symbol for INDOOR USE ONLY Symbol for MANUFACTURE DATE Airon Body Analysis Scale LS 202 B offers you a seamless way to manage your health Please be aware t...

Страница 4: ...Batteries 1 5V each 3 User Manual Overview Overview Device Components Battery Compartment UNIT Button LCD Display Electrode Electrode Stone Pound Bioelectrical Impedance Analysis Kilogram Data transm...

Страница 5: ...ooth function in line with BLE Technical Specifications as well as BLP Protocol established by global organization Bluetooth SIG are capable to receive your personal health data Just simply install th...

Страница 6: ...suring Select Measurement Unit Daily Measurement With original SENSE ON patent technology LS 202 B B will automatically switch on as you step on the platform barefooted When your scale is successfully...

Страница 7: ...ocated on the soft ground such as a carpet OR on a rugged surface Please place the device on a flat hard surface Warm up your hands and feet to resume blood circulation and then measure again Cold bod...

Страница 8: ...Batteries not yet installed Worn batteries Low battery Install the batteries Please refer to Insert the Batteries Replace all four batteries in the same time Please purchase the authorized batteries...

Страница 9: ...in normal use for a period of TWO years from the date of retail purchase This warranty does NOT cover damages caused by misuse or abuse including but not limited to Failure caused by unauthorized rep...

Страница 10: ...21 1 24 24 20 20 1 29 29 1 32 32 16 1 23 23 1 26 26 22 22 1 30 30 1 33 33 14 4 14 70 63 15 21 63 57 22 24 57 55 25 55 37 4 20 70 58 21 29 58 52 30 32 52 49 33 49 37 16 50 59 17 1 24 24 1 27 27 23 23...

Страница 11: ...E EQUIPMENT and ME SYSTEMS that are not LIFE SUPPORTING Guidance and manufacturer s declaration electromagnetic immunity IMMUNITY test IEC 60601 TEST LEVEL Compliance level Electromagnetic environment...

Страница 12: ...Separation distance according to frequency of transmitter m Rated maximum output power of transmitter W 150 kHz to 80 MHz P V d 5 3 1 80 MHz to 800 MHz 800 MHz to 2 5 GHz 1 0 0 1 0 1 0 1 0 0 1 For tr...

Отзывы: